PubMed HealthSearch

PubMed · 8530200

Elastomeric valves, a new design.

Abstract

The convex bileaflet valve replaces the flat biflap inflow valve designed by Long Sheng Yu and the tricusp semilunair outflow valve. One reason is easier manufacturing. Convex bileaflet valves are developed for the 11, 20, 40, 70 and 140cc ventricles. Testing included curves (Cardiac Output versus Venous Pressure, Cardiac Output versus Heart rate), flow visualization studies, paint and bloodbag studies. The curves and flow visualization were done by connecting ventricles to one of our standard mock circulations. Paint and bloodbag studies were done by connecting the hearts to a bloodbag, but the bag was filled with water for the paint studies. The curves show high cardiac output, even with pumping at high heart rates (150 BPM+). The flow visualization shows a good stream through the sinus Valsalvae. No stagnating flow is visible. The bloodbag studies which provoke thrombosis show it on the edges of the heart valves, and little in the groove between the valve and the sinus Valsalvae. Heparninzation prevents the thrombosis. Results of our tests were good. The convex bileaflet valve seems to have good future.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M H Hulsbergen, S Topaz, A Kumar, N D Bishop, A Shelton, S Granger, B Y Chiang, L De Boer, R A Luikenaar, S F Mohammed. 1995. Elastomeric valves, a new design.. https://pubmed.ncbi.nlm.nih.gov/8530200/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Radiation dose perturbation at tissue-titanium dental interfaces in head and neck cancer patients.

PURPOSE: To determine the dose perturbation effects at the tissue-metal implant interfaces in head and neck cancer patients treated with 6 MV and 10 MV photon beams. METHODS AND MATERIALS: Phantom measurements were performed to investigate the magnitude of dose perturbation to the tissue adjacent to the titanium alloy implants with (100 mu and 500 mu thick) and without hydroxylapatite (HA) coating. Radiographic and radiochromic films were placed at the upper (and lower) surface of circular metal discs (diameter x thickness: 15 x 3.2, 48 x 3.2, 48 x 3.8 mm2) in a solid water phantom and were exposed perpendicular to radiation beams. The dosimeters were scanned with automatic film scanners. Using a thin-window parallel-plate ion chamber, dose perturbation were measured for a 48 x 3.2 mm2 disc. RESULTS: At the upper surface of the tissue-dental implant interface, the radiographic data indicate that for 15 x 3.2 mm2 uncoated, as well as 100 mu coated discs, dose perturbation is about +22.5% and +20.0% using 6 MV and 10 MV photon beams, respectively. For 48 x 3.2 mm2 discs, these values basically remain the same. However, for 48 x 3.8 mm2 discs, these values increase slightly to about +23.0% and +20.5% for 6 MV and 10 MV beams, respectively. For 48 x 3.2 mm2 discs with 500 mu coating, dose enhancement is slightly lower than that obtained for uncoated and 100 mu coated discs for each beam energy studied. At the lower interface for 15 x 3.2 mm2 and 48 x 3.2 mm2 uncoated and 100 mu coated discs, dose reduction is similar and is about -13.5% and -9.5% for 6 MV and 10 MV beams, respectively. For 48 x 3.8 mm2 discs, dose reduction is about -14.5% and -10.0% for 6 MV and 10 MV beams, respectively. For 48 x 3.2 mm2 discs with 500 mu coating, the dose reduction were slightly higher than those for uncoated and 100 mu coated discs. CONCLUSIONS: For the beam energies studied, dose enhancement is slightly larger for the lower energy beam. The results of dose perturbation were similar for 100 mu coated and uncoated discs. These results were slightly lower for the 500 mu coated discs but are not clinically significant. The dosimetry results obtained from radiochromic films were similar to the ones obtained from radiographic film. The dose enhancement results obtained from ion chamber dosimetry are higher than those obtained from film dosimetry. The ion chamber data represent the data at "true" tissue-titanium interface, whereas the ones obtained from film dosimetry represent the data at film-titanium interface.

Biocompatible Materials

Fibrinogen binding and platelet retention: relationship with the thrombogenicity of catheters.

One of the major problems in the use of catheters is their thrombogenicity, since the embolization of clots near the central nervous system or the coronary arteries can cause permanent damage. In this work we have compared the in vivo thrombogenicity of four different angiography catheters and their in vitro activation of fibrinogen binding and platelet retention. The thrombogenicity of catheters has been evaluated in angiographic conditions by kinetic evaluation of the reduction of blood flow rate through the catheters. The binding of adhesive proteins (fibrinogen and von Willebrand factor [vWF] was studied in vitro using a direct-ELISA technique after circulation of anticoagulated whole blood through sections of catheters. The retention of platelets was studied in vitro using 111Indium-labelled platelets. Fibrinogen binding and platelet retention both seem to be good predictors of catheter thrombogenicity, fibrinogen being the better of the two. The most thrombogenic material has the highest fibrinogen and platelet retention rate. This study also confirms the inefficiency of albumin precoating for the prevention of fibrinogen deposition. The determination of fibrinogen deposition by direct-ELISA technique and platelet retention rate is very useful for preclinical testing of catheters.

Biocompatible Materials