PubMed HealthSearch

PubMed · 8531397

[Laboratory systematization].

Abstract

We have built a clinical laboratory system incorporating automatic analyzers (chemistry, immunology and hematology) and automatic sample dispensers. This laboratory system is linked with a main computer through communication lines. Patient's serum specimens are first treated with an automatic sample dispenser and then analyzed at random with automatic analyzers. Specimens which need to be analyzed in commercial laboratories can be dispensed with another automatic sample dispenser. Consequently, cost of reagents and overtime payment can be reduced. Security for avoiding infectious diseases is provided for laboratory technicians. Our clinical laboratory system can reduce the turnaround time for reporting diagnostic data to 30 to 40 minutes. Also, this system can reduce personnel expenses. However, the profits are still not satisfactory compared with those of commercial laboratories. Therefore, we will continue to make every effort to cut down the expenses for the future.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Murakami. 1995. [Laboratory systematization].. https://pubmed.ncbi.nlm.nih.gov/8531397/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Weight-based accuracy of parenteral nutrient solutions prepared with an automated compounder.

The accuracy of an automated compounder in preparing parenteral nutrient solutions was evaluated. A total of 480 1-, 2-, and 3--L solutions representing 68 different formulations, some containing electrolytes, were prepared with two Automix devices. The actual weight of the final product was compared with the calculated weight of all ingredients plus the weight of the empty final container. The weight of each ingredient was calculated by multiplying the specific gravity by the volume. A solution was considered acceptable if it weight 95% to 105% of the estimated weight. Only two bags were outside the acceptable range. The mean weight as a percentage of estimated weight for all bags was 100.07 +/- 1.26%. Of the 480 nutrient solutions prepared by an automated compounder, 478 were within 5% of their expected final weight.

Automation

A DNA cycle sequencing reaction that minimizes compressions on automated fluorescent sequencers.

We recently demonstrated that most band compressions (>70%) on DNA sequencing gels result from the presence of a single sequence motif, 5'-YGN1-2AR-3', where Y and R indicate base-pairing pyrimidine and purine residues, respectively. This finding raised the possibility that the use of 7-deaza-dATP instead of dATP in chain termination sequencing reactions would resolve most of the band compressions. Thus, we examined the effects of 7-deaza-dATP on DNA sequencing using thermostable DNA polymerases. The results indicate that the replacement of dATP with 7-deaza-dATP in conventional cycle sequencing reactions can successfully eliminate most band compressions without sacrificing sequencing performance.

Automation