PubMed · 8534311
Distraction for ankle arthroscopy.
Abstract
Distraction has proven to be usefull for arthroscopic visualisation and instrumental access to some ankle pathology. A distraction technique using a single calcaneal pin combined with the installation of the patient on a fracture table is described. The method has already been used by the authors in more than 100 ankle arthroscopy procedures without distraction-related complications.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
P P Casteleyn, F Handelberg. 1995. Distraction for ankle arthroscopy.. https://doi.org/10.1016/0749-8063(95)90146-9