PubMed Health⌕ Search

PubMed · 8555615

A dynamic intravascular artificial lung.

Abstract

Intravascular lung assist devices (ILADs) must transfer sufficient amounts of oxygen and carbon dioxide to and from limited surface areas. It has become apparent that passive devices, i.e., those without an active means for enhancing transfer, cannot achieve sufficient transfer within the space available. High speed rotation or oscillation of fiber sheets can increase transfer rates up to 800% over the rates achieved by a stationary device, judiciously configured fiber sheets cause an additional benefit when rotated: reduced resistance to blood flow across the device. The authors have developed a series of device prototypes based on these principles of transfer augmentation and minimization of flow resistance. The prototypes are small enough to fit inside the vena cava, with transfer surface areas ranging from 0.1 m2 to 0.5 m2. Transfer rates of O2 up to 53 ml/min and CO2 up to 51 ml/min and fluxes of 208 ml (min/m2) for O2 and 310 ml (min/m2) for CO2 have been achieved.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A J Makarewicz, L F Mockros, R W Anderson. A dynamic intravascular artificial lung.. https://doi.org/10.1097/00002480-199407000-00099

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Artificial muscles based on liquid crystal elastomers.

This paper presents our results on liquid crystal (LC) elastomers as artificial muscle, based on the ideas proposed by de Gennes. In the theoretical model, the material consists of a repeated series of main-chain nematic LC polymer blocks, N, and conventional rubber blocks, R, based on the lamellar phase of a triblock copolymer RNR. The motor for the contraction is the reversible macromolecular shape change of the chain, from stretched to spherical, that occurs at the nematic-to-isotropic phase transition in the main-chain nematic LC polymers. We first developed a new kind of muscle-like material based on a network of side-on nematic LC homopolymers. Side-on LC polymers were used instead of main-chain LC polymers for synthetic reasons. The first example of these materials was thermo-responsive, with a typical contraction of around 35-45% and a generated force of around 210 kPa. Subsequently, a photo-responsive material was developed, with a fast photochemically induced contraction of around 20%, triggered by UV light. We then succeeded in preparing a thermo-responsive artificial muscle, RNR, with lamellar structure, using a side-on nematic LC polymer as N block.Micrometre-sized artificial muscles were also prepared. This paper illustrates the bottom-up design of stimuli-responsive materials, in which the overall material response reflects the individual macromolecular response, using LC polymer as building block.

Artificial Organs↗

A design framework to model retinas.

Neuro-engineering is providing biomedical engineers with technology to interface the nervous system, which is useful to create prosthetic devices to palliate sensorial or motor disabilities. Motivated by the success of cochlear implants for deaf patients, we are now facing the challenge of creating a prosthetic visual system for the blind. An artificial retina whose response to stimuli can be matched to biological ones is required. To make easier the task of modeling, tuning and testing these retinal models, we have created a software tool that allows flexible and parametric definition and testing of retina-like models. The program can be fed with a variety of video or image sources, and the results can be easily compared to biological recordings of retinal ganglionar activity in response to the same stimuli. This tool can be useful, not only for this prosthetic purpose, but for any other research involving bio-inspired image processing with a neuromorphic output.

Artificial Organs↗