OBJECTIVES: To evaluate the performance of a newly developed single breath CO2 analysis station in measuring the airway deadspace in a lung model (study 1), and then to quantify the bias and precision of the physiologic deadspace measurement in a surfactant-depleted animal model (study 2). DESIGN: A prospective bench validation of a new technique of airway deadspace measurement using a criterion standard (study 1); a prospective, animal cohort study comparing a new technique of physiologic deadspace measurement with a reference method (Bohr-Enghoff method) (study 2). SETTING: A bench laboratory and animal laboratory in a university-affiliated medical center. SUBJECTS: A lung model (study 1), and adult sheep with induced surfactant deficiency (saline lavage) (study 2). METHODS: The single breath CO2 analysis station consists of a mainstream capnometer, a variable orifice pneumotachometer, a signal processor, and computer software with capability for both on- and off-line data analysis. Study 1: We evaluated the accuracy of the airway deadspace calculation using a plexiglass lung model. The capnometer and pneumotachometer were placed at the ventilator Y-piece with polyvinyl chloride tubing added to simulate increased airway deadspace. Segments of tubing were sequentially removed during each testing session to simulate decreasing deadspace. The calculated airway deadspace was derived from the single breath CO2 plot and compared with the actual tubing volume using least-squares linear regression and paired t-tests. Study 2: The accuracy of the physiologic deadspace measurement was examined in a saline-lavaged animal model by comparing the physiologic deadspace calculated from the single breath CO2 analysis station with values obtained using the Enghoff modification of the Bohr equation: deadspace/tidal volume ratio = (PaCO2-mixed expired PCO2)/PaCO2. MEASUREMENTS AND MAIN RESULTS: Study 1: Thirty-six measurements of calculated airway deadspace were made and compared with actual circuit deadspace during four different testing conditions. Measured airway deadspace correlated significantly with actual circuit deadspace (r2 = .99). The proportional error of the method was -0.8% with a 95% confidence interval from -3.6% to 1.9%. Study 2: A total of 27 pairs of measurements in four different animals were available for analysis. The derived physiologic deadspace/tidal volume ratio significantly correlated with the value obtained using the Bohr-Enghoff method (r2 = .84). The bias and precision of our physiologic deadspace calculation were .02 and .02, respectively, and the mean percent difference for the physiologic deadspace calculated from the single breath CO2 analysis station was 2.4%. CONCLUSIONS: Our initial experience with the single breath CO2 analysis station indicates that this device can reliably provide on-line evaluation of the single-breath CO2 waveform. In particular, estimation of the airway and physiologic deadspace under a variety of testing conditions was consistently within 5% of actual values. We feel that with further application and refinement of the technique, single breath CO2 analysis may provide a noninvasive, on-line monitor of changes in pulmonary blood flow.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J H Arnold, J E Thompson, L W Arnold. 1996. Single breath CO2 analysis: description and validation of a method.. https://doi.org/10.1097/00003246-199601000-00017

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Protocol for Detecting and Sequencing Chikungunya Virus from Field-Collected Mosquitoes.

Arboviral diseases represent a major public health challenge, especially in tropical regions where environmental conditions may favor the proliferation and spread of mosquito vectors. Thus, early and accurate detection of chikungunya virus (CHIKV) in mosquito populations can be a valuable tool for effective surveillance of circulating variants and for identifying new viral introductions. Given the challenges of detecting arboviruses in field-captured mosquitoes, we describe an integrated workflow for CHIKV molecular detection and whole-genome sequencing. This protocol includes mosquito homogenization using a bead-based mechanical disruptor, RNA extraction using TRIzol reagent with minor modifications, molecular screening using CHIKV-specific RT-qPCR, and whole-genome amplification followed by sequencing on Illumina platforms. Despite the protocol being optimized for individual mosquitoes, it results in high-quality RNA suitable for both entomological surveillance and genomic analysis. As this protocol allows recovery of complete CHIKV genomes from mosquito specimens, it can serve as a basis for genomic epidemiology studies, enabling monitoring of viral diversity and lineage dynamics, and facilitating early detection of emerging variants to support timely and targeted public health interventions in endemic and at-risk regions.

Animals↗

Genomic Profiling of Chromatin State Using CUT&Tag.

Alterations in chromatin state, mediated through histone modifications and the incorporation of histone variants, are fundamental to establishing transcriptional networks and cell identity. Recent advances in low-input epigenome profiling methods, such as CUT&Tag and CUT&RUN, have enabled the study of chromatin states from very limited starting materials. In this chapter, we describe procedures for generating CUT&Tag libraries to profile histone modifications and histone variants in early-developing zebrafish embryos.

Animals↗

Relaxin-2: Shaping the Proteomic Landscape of Skeletal Muscle Physiology, Glucose Trafficking, and Mitochondrial Function in Rat.

Relaxin-2 is a hormone with robust beneficial effects on the heart and blood vessels and potential as a therapy for cardiovascular (CV) disease. Considering the interorgan communication between skeletal muscle and heart, and the relation between muscle quality/composition and CV events, we hypothesize that relaxin-2 may regulate skeletal muscle physiology and metabolism. We aim to evaluate the impact of relaxin-2 on the proteome of skeletal muscle from healthy Sprague-Dawley rats. Animals were treated with 0.4 mg/kg/day of serelaxin (recombinant form of human relaxin-2) or vehicle (PBS) for 2 weeks employing subcutaneous osmotic minipumps. Skeletal muscle protein identification and quantification were performed by LC-MS/MS using a Data-Independent Acquisition (DIA)-Sequential Window Acquisition of All Theoretical Fragment Ion Spectra (SWATH) method. SWATH/MS quantitative analysis identified that relaxin-2 significantly decreased 95 proteins and significantly increased 32 proteins in rat skeletal muscle when compared to control rats. From these, 34 proteins were associated with muscle function, myogenesis, muscle differentiation and/or regeneration, 20 are mitochondrial proteins (six from the complexes of the electron transport chain), and 10 proteins participate in glucose metabolism. Qualitative data-dependent workflow analysis identified 35 proteins exclusive to the skeletal muscle of the relaxin-2-treated group: eight proteins related to processes of skeletal muscle function (size, ion homeostasis or organization of caveolae structures and cytoskeleton) and myogenesis, and two proteins involved in muscle differentiation. Our work highlighted for the first time the role of relaxin-2 in crucial processes of muscle physiology and energetic metabolism, which could influence several processes involved in myopathy and CV.

Animals↗