A microchip glucose sensor.

Abstract

A major problem in development of a glucose sensor for use in an implantable artificial pancreas is the lack of reproducibility in signals from sensor to sensor. Each glucose sensor fabricated with currently used methods has a unique response to varying levels of glucose concentration and thus needs to be individually calibrated before use. We have adapted microchip manufacturing techniques for the fabrication of electrochemically based glucose sensors with standardized and reproducible function. Scanning electron microscopic study of the resulting electrode surfaces shows them to be smooth and featureless at all levels of magnification. X-ray diffraction analysis of the electrodes indicates preferential exposure of the [1,1,1] crystal interface. Cyclic voltammetry evaluation of initial sensor response to varying glucose concentrations shows excellent sensor to sensor reproducibility for all sensors made with the same underlayment. Sensors made with titanium underlayment appear to be more differentiated and thus more sensitive to variations in glucose concentration than are sensors with chromium underlayment. Although the initial response of microchip glucose sensors appears to be standardized and reproducible, additional development of an appropriate electrical insulation material is required before long-term study of signal stability is feasible.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J F Patzer, S J Yao, W Xu, T L Day, S K Wolfson, C C Liu. A microchip glucose sensor.. https://doi.org/10.1097/00002480-199507000-00041

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The calcar femorale: a tale of historical neglect.

The term calcar femorale (originally referring to a bony spur projecting into the cancellous tissue of the base of the femoral neck) differs from most anatomical terms in that it has developed separate meanings in different areas of use. In particular, its present meaning for most orthopedic surgeons differs from its classical anatomical significance. This work shows that the classical, "textbook" anatomical interpretation-usually attributed to Merkel (1874, cited by Harty, 1957, J. Bone Joint Surg. [Am.] 39:625-630)-is not entirely correct, being based on an incomplete appreciation of the true nature of the three-dimensional structure of the upper end of the femur. Though Humphry (1858, A Treatise on the Human Skeleton, Cambridge, England: Macmillan) was aware of the importance of the third dimension, it was the largely neglected work of Dixon (1910, J. Anat. Physiol., 44:223-230), itself published to draw attention to the ideas of Krause (1909, in Bardeleben's Handbuch der Anatomie des Menschen, Jena: Gustav Fischer), which indicated the true nature of the calcar femorale and the limitations of Merkel's view. Dixon's work has been developed and consolidated by others such as Garden (1961, J. Bone Joint Surg. [Br.] 43:576-589), who was apparently unaware of Dixon, just as Dixon himself appears to have been unaware of the work of Bigelow (1875, published in Bigelow, 1900, The Mechanisms of Dislocations and Fracture of the Hip, Boston: Little, Brown), which pre-empted one of his major concepts. Even earlier work by Bigelow (1869, published in Bigelow; 1900, The Mechanisms of Dislocations and Fracture of the Hip, Boston: Little, Brown) appears to have pre-empted that of Merkel. The adoption of the three-dimensional, "Dixon concept" of the bony anatomy of the upper end of the femur leads to an entirely different set of structural engineering analogies from those two-dimensional ones which have become commonplace since the work of Ward (1838, cited by Garden, 1961, J. Bone Joint Surg. [Br.] 43:576-589) and Wolff (1870, cited by Keith, 1919, Menders of the Maimed, London: Frowde and Hodder & Stoughton).

Biomedical Engineering

In-shoe biaxial shear force measurement: the Kent shear system.

The Kent shear system is introduced and preliminary clinical results are presented. A technique utilising copolymer piezoelectric film has allowed the manufacture of biaxial in-shoe transducers capable of simultaneously measuring two orthogonal shear forces. Bipedal measurements are carried out inside everyday footwear over multiple footsteps.

Biomedical Engineering