Quality control for SPECT systems.

Abstract

A comprehensive set of acceptance tests is the basis for an effective quality control program. Acceptance tests indicate whether the scintillation camera meets published specifications but should also include evaluation of certain parameters not specified by the vendor but that can seriously affect image quality. Once a camera is "accepted," initial quality control tests serve as a benchmark for future measurements. Tomographic systems must be subjected to the same basic quality control program as planar cameras. Flood field images must be acquired and evaluated daily; spatial resolution must be tested once each week. Less frequently, parameters such as multiple-window spatial registration, collimator uniformity, system sensitivity, and camera "dead time" should be evaluated. Single photon emission computed tomographic systems require additional tests to ensure optimum performance. Center-of-rotation calibration and verification of detector registration are needed to avoid losses of spatial resolution. Flood corrections based on high-count images eliminate residual detector nonuniformiaties and correct for subtle collimator defects. Pixel size must be calibrated to avoid errors in attenuation correction and distortion when cardiac and brain reorientation software is used. Completed clinical studies must be checked for unacceptable patient movement and incomplete views. A quality control program may be time-consuming, but, from the standpoint of maximum benefit to patients and confidence in clinical interpretations, there is no alternative.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L S Graham. 1995. Quality control for SPECT systems.. https://doi.org/10.1148/radiographics.15.6.8577970

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts

The radiographic and imaging characteristics of porous tantalum implants within the human cervical spine.

STUDY DESIGN: Seven cadaveric cervical spines were implanted with a porous tantalum spacer and a titanium alloy spacer, and their radiographic and imaging characteristics were evaluated. OBJECTIVE: To determine the radiographic characteristics of porous tantalum and titanium implants used as spacers in the cervical spine. SUMMARY OF BACKGROUND DATA: Anterior decompressive surgery of the disc space or the vertebral body creates a defect that frequently is repaired with autologous bone grafts to promote spinal fusion. Donor site morbidity, insufficient donor material, and additional surgical time have spurred the development of biomaterials to replace or supplement existing spinal reconstruction techniques. Although the promotion of a solid bony fusion is critical, the implanted biomaterial should be compatible with modern imaging techniques, should allow visualization of the spinal canal and neural foramina, and should permit radiographic assessment of bony ingrowth. METHODS: Cadaveric spines containing the implants were imaged with plain radiography, computerized tomography, and magnetic resonance imaging. The image distortion produced by the implants was determined qualitatively and quantitatively. RESULTS: The tantalum and titanium spacers were opaque on plain radiographic films. On computed tomographic scans, more streak artifact was associated with the tantalum implants than with the titanium. On magnetic resonance imaging, the porous tantalum implant demonstrated less artifact than did the titanium spacer on T1- and T2-weighted spin echo and on T2*-weighted gradient-echo magnetic resonance images. Overall, the tantalum implant produced less artifact on magnetic resonance imaging than did the titanium spacer and therefore allowed for better visualization of the surrounding bony and neural structures. CONCLUSION: The material properties of titanium and porous tantalum cervical interbody implants contribute to their differential appearance in different imaging methods. The titanium implant appears to image best with computed tomography, whereas the porous tantalum implant produces less artifact than does the titanium implant on several magnetic resonance imaging sequences.

Artifacts