PubMed HealthSearch

PubMed · 8591215

Multimedia cardiac catheterization record document system.

Abstract

In this paper, we present the design and implementation of a multimedia cardiac catheterization record (CCR) system. A traditional CCR contains medical report, electrocardiograms, X-ray images, and possibly video sequences for angiograms. The physicians found it difficult to access and manage these multimedia information easily. Current advances in multimedia technology has made possible the authoring, storage and presentation of these medical information in a systematic and easily-accessible way. This paper discusses the background and rationale that led to the design and implementation of a cost-effective multimedia medical document system framework and prototype.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H S Horace, K C Law, S L Chan. 1995. Multimedia cardiac catheterization record document system.. https://pubmed.ncbi.nlm.nih.gov/8591215/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Nothin' but 'net?

Explore the source record for details and available documents.

Cardiac Catheterization

Clinical and electrophysiologic features of idiopathic left ventricular aneurysm with sustained ventricular tachycardia.

We examined 10 patients with idiopathic left ventricular (LV) aneurysm with sustained ventricular tachycardia (VT) (Id-An group), and compared them with those in 16 age- and sex-matched patients who had postinfarction aneurysm and VT (MI-An group) to clarify detailed clinical and electrophysiologic characteristics of idiopathic LV aneurysm. The clinical and laboratory data and results of electrocardiography, electrophysiologic, and morphologic examinations in the two groups were compared. In the Id-An group, the LV aneurysms were located more often at the posterior and/or inferior wall, while in the MI-An group, they were more often located at the anterior and/or apical wall (P<0.001). The LV end-diastolic volume index was significantly smaller and the LV ejection fraction was significantly higher in the Id-An group (P<0.001). The size of the aneurysm and the area with abnormal electrograms in the Id-An group were significantly smaller than those in the MI-An group (P<0.005 and P<0.001, respectively). The inducibility of VT was high in both groups, and ventricular pacing during VT showed entrainment phenomenon in most of the patients. Thus, in both groups, the abnormal electrograms were closely associated with the wall motion abnormality, and reentry was suggested as the mechanism of VT. In the Id-An group, since the lesions were anatomically and electrophysiologically confined to the posterior and/or inferior wall, the global LV function was more well preserved compared with the MI-An group.

Cardiac Catheterization

Validation of the conductance catheter method for measurement of ventricular volumes under varying conditions relevant to cardiac surgery.

The development of the conductance catheter method has enabled continuous measurement of intraventricular volume in vivo, thus making assessment of pump performance of the heart in vivo possible using pressure-volume analysis. However, this method has not been validated under conditions where pump rate, conductance, viscosity, and temperature of the fluid in the heart chamber is changed as happens in cardiac surgery. To validate the method, pressure-volume data were measured by conductance catheter in a physical model of the human left ventricle. The volume, salinity, viscosity, and temperature of the fluid inside the model were rigorously controlled. The measured pressure-volume data were compared with the actual values to assess the accuracy and dependence of the conductance-measured volumes on salinity, viscosity, temperature, and pump rate. Conductance-measured volumes were not significantly different over a range of heart rates extending from 60 to 100 beats/min, and they were not significantly different over a salinity range of 0.2 to 2 normal saline, a viscosity range of 2.7 to 3.5 centipoise, or over a temperature range of 20 degrees C to 39 degrees C. The percentage errors between actual stroke volumes and conductance-derived volumes were of the order of 10% on average. Our data shows that for a broad range of conditions normally encountered during cardiac surgery, there is no dependence of conductance-measured volume on heart rate, viscosity, temperature, or salinity, provided the correct value of fluid resistivity is used.

Cardiac Catheterization