PubMed Health⌕ Search

PubMed · 8599695

A microcomputer-based system for coronary artery Doppler studies.

Abstract

Intra-vascular Doppler catheters are becoming popular as research tools for studies of the coronary circulation. Velocity estimates can be obtained from Doppler signals sampled with such catheters, and used to calculate various derived parameters which can then be correlated with the haemodynamic situation under investigation. This note discusses the requirements necessary for a system to perform the acquisition of the high-frequency Doppler signals obtained from catheter-tipped transducers, and a system developed to capture, process and store Doppler, ECG and pressure signals is described. Software used to calculate parameters from the stored waveforms is discussed and examples of the system outputs presented.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Moraes, D H Evans, D P DeBono. 1995. A microcomputer-based system for coronary artery Doppler studies.. https://doi.org/10.1088/0967-3334%2F16%2F4%2F008

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Stress echocardiography in 11 patients with symptoms of ischemia and a myocardial bridge: no indication of a causal connection in 10 cases].

OBJECTIVE: To determine whether in patients with a myocardial bridge, systolic compression of the affected coronary branch may cause cardiac ischaemia and is of clinical relevance. DESIGN: Pilot inventory. METHOD: In 11 consecutive patients with an established myocardial bridge who presented with possible ischaemic symptoms angiographic dobutamine stress-echocardiography was used to visualize hypokinesia caused by ischaemia in the area ofmyocardium supplied by the bridged artery. RESULTS: Hypokinesia was observed in the area supplied by the bridged artery in one of the patients (9%). The symptoms in the other patients were not associated with the bridge. CONCLUSION: The clinical relevance of myocardial bridging appeared to be smaller than is generally assumed. In patients with known myocardial bridging and symptoms that could be caused by myocardial ischaemia, it should first be established that the bridge is actually causing the ischaemia before any therapeutic intervention aimed at the bridge is undertaken.

Coronary Vessels↗

Double orifice tricuspid valve in an infant with tetralogy of Fallot.

Atrioventricular valve duplication, also known as double orifice valve, is an excitingly rare anomaly that can involve either the mitral or more uncommonly the tricuspid valve. Herein we describe a case of a double orifice tricuspid valve that prejudiced the complete repair in a symptomatic infant with tetralogy of Fallot.

Coronary Vessels↗