PubMed HealthSearch

PubMed · 8619200

Randomized controlled trials in surgery: Issues and problems.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R S McLeod, J G Wright, M J Solomon, X Hu, B C Walters, A l Lossing. 1996. Randomized controlled trials in surgery: Issues and problems.. https://doi.org/10.1016/s0039-6060(96)80254-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Measurements of exhaled nitric oxide with the single-breath technique and positive expiratory pressure in infants.

The aim of this study was to adapt the single-breath technique with positive expiratory pressure to measure exhaled nitric oxide (eNO) in infants. We hypothesized that exhaled eNO was greater in wheezy than in healthy infants. We studied 30 infants (16 wheezy and 14 healthy). The forced expiratory volume in 0.5 s (FEV0.5) was determined with the raised volume rapid thoracic compression technique, and eNO was measured during constant expiratory flow with a rapid-response chemiluminescence analyzer. After passive inflation to a preset pressure of 20 cm H2O, thoracic compression with an inflatable jacket caused forced expiration to occur through a face-mask with an expiratory flow resistor attached. During the forced expiration, the jacket pressure was increased to maintain a constant driving mouth pressure and hence a constant expiratory flow (50 ml/s). The mean level of eNO in the wheezy infants (31.8 ppb) was significantly higher than the level in healthy infants (18.8 ppb) (p = 0.03). A family history of atopy in parents was associated with increased eNO levels (p < 0.001) independent of age, sex, weight, length, wheezing, and FEV0.5. We conclude that the single-breath technique with positive expiratory pressure is a feasible method for measuring eNO in infants. Levels of eNO were significantly higher in wheezy infants and in those with a family history of atopy.

Feasibility Studies

The use of adaptive radiation therapy to reduce setup error: a prospective clinical study.

PURPOSE: Adaptive Radiation Therapy (ART) is a feedback treatment process that optimizes a patient's treatment according to the patient specific information measured during the course of treatment. Utilizing an electronic portal imaging device (EPID) and a computer-controlled multileaf collimator (MLC), the ART process is currently being implemented in our clinic to improve the treatment accuracy by compensating for the treatment setup error. A prospective study was conducted to evaluate the feasibility and efficacy of the ART process for clinical use. METHODS AND MATERIALS: The prospective study included 20 patients who underwent conventional radiotherapy on a linear accelerator equipped with an EPID and a MLC. No specific changes were made in the routine clinical procedures except daily portal images were obtained for each treatment field. Two-dimensional setup error for each treatment field was then measured offline using a software tool. The measured setup errors from initial treatment days were used to predict the systematic and random setup errors for each treatment field. An adjustment decision was made if the predicted systematic error was larger than or equal to 2 mm. Furthermore, the treatment field was extended if the predicted random setup error could not be effectively compensated by the predefined treatment setup margin. Instead of the conventional approach of patient repositioning, setup adjustment was implemented by reshaping the MLC field. The entire process from measuring setup error to reshaping the MLC field was performed offline through a computer network. After completion of a patient's treatment, the systematic and random setup errors after adjustment were compared with those predicted prior to the adjustment. The accuracy of the adjustment, and the reliability and stability of the process were analyzed. RESULTS: Treatment fields of 13 patients were modified to correct for systematic errors. The mean systematic error was 4 mm with a range of 2 to 7 mm before adjustment. It was reduced to 0.5 mm with a range of 0.2 to 1.4 mm after adjustment. There was no significant difference in random setup errors before and after adjustment. The ART process was found to be stable, as more than 95% of patient specific setup margins were predictable within 1 mm using the first four to nine fractions of treatment, confirming the feasibility of treatment plan reoptimization with the ART process. CONCLUSIONS: The prospective study demonstrates that the ART process can be effectively implemented in routine clinical practice to improve treatment accuracy. This process is also ready to be further extended to reoptimize the treatment plan by incorporating the predicted patient specific setup variation.

Feasibility Studies

Flotation as a remediation technique for heavily polluted dredged material. 1. A feasibility study.

The flotation behaviour of highly polluted dredged material was investigated at different pH values by mechanical agitated (Denver) flotation. Up to 80% of cadmium, copper, lead and zinc could be concentrated in the froth layer which represented only 30% of the total mass. The maximum specificity for heavy metals, defined as the concentrating factor, was obtained at pH 8-9. The maximum recovery of heavy metals on the other hand was found to be reached at elevated pH values (pH 12). In addition the specificity of the flotation process for the transition metals could be assigned to their presence as metal sulphides in the dredged material. However, the interaction with organic matter is an important factor in determining their flotability. The carbonate fraction was irrelevant for the flotation behaviour of heavy metals.

Feasibility Studies