PubMed Health⌕ Search

PubMed · 8626185

Parametric signal restoration using artificial neural networks.

Abstract

The problem of parametric signal restoration given its blurred/nonlinearly distorted version contaminated by additive noise is discussed. It is postulated that feedforward artificial neural networks can be used to find a solution to this problem. The proposed estimator does not require iterative calculations that are normally performed using numerical methods for signal parameter estimation. Thus high speed is the main advantage of this approach. A two-stage neural network-based estimator architecture is considered in which the vector of measurements is projected on the signal subspace and the resulting features form the input to a feedforward neural network. The effect of noise on the estimator performance is analyzed and compared to the least-squares technique. It is shown, for low and moderate noise levels, that the two estimators are similar to each other in terms of their noise performance, provided the neural network approximates the inverse mapping from the measurement space to the parameter space with a negligible error. However, if the neural network is trained on noisy signal observations, the proposed technique is superior to the least-squares estimate (LSE) model fitting. Numerical examples are presented to support the analytical results. Problems for future research are addressed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Materka, S Mizushina. 1996. Parametric signal restoration using artificial neural networks.. https://doi.org/10.1109/10.486256

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗