Epileptiform electroencephalographic patterns.

Abstract

Electroencephalography (EEG) is the most useful test for assessment of patients with epilepsy. It can help establish the diagnosis of epilepsy and determine the type of seizure disorder and its site of origin. Epileptiform abnormalities in the EEG tracing may be focal or generalized. The main types of focal epileptiform discharges arise from the temporal, frontal, occipital, centroparietal, centrotemporal, and midline regions of the brain. Generalized epileptiform discharges consist of the 3-Hz spike-and-wave, slow spike-and-wave, atypical spike-and-wave, paroxysmal fast activity, and hypsarrhythmic patterns. Status epilepticus is manifested by continuous epileptiform discharges or recurrent seizure activity without interim recovery, which can occur in a generalized or focal manner. Benign epileptiform variants unassociated with seizures can also be present in the EEG. Included in this category are the "14 & 6" positive bursts, small sharp spikes, wicket waves, 6-Hz spike-and-wave discharges, and rhythmic temporal theta activity. The EEG findings should be interpreted in the context of the overall clinical picture.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B F Westmoreland. 1996. Epileptiform electroencephalographic patterns.. https://doi.org/10.4065/71.5.501

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Epileptic nystagmus in infancy.

Epileptic nystagmus (EN) is a rare form of nystagmus that occurs only during epileptic seizures. We report an infantile case in which EN was first noted at 10 days of age. Electronystagmography showed a right-beating nystagmus with predominantly linear slow phases that traversed the midline. Neuro-imaging revealed dysplasia of the left middle temporal gyrus extending posteriorly into the parieto-occipital cortex. The right hemisphere and subcortical structures appeared normal. Perfusion studies demonstrated interictal hypoperfusion with ictal hyperperfusion in the left temporal lobe. Electrocorticography demonstrated spiking over the left temporal-parieto-occipital region. Following extensive surgical resection of this area and weaning of anti-convulsants, the child has remained seizure-free without nystagmus. This case demonstrates the cortical origin of EN, and shows that infant cortex has functioning efferent connections to brainstem oculomotor centres from 10 days of age.

Electroencephalography

Performance of real time separation of multi-neuron recordings with a DSP32C microprocessor.

The performance of a method for sorting of waveforms in multi-neuron data (Gädicke and Albus, 1995) is evaluated by using artificial spike patterns generated by the computer and by adding to these spikes noise or free running sine waves of varying frequency and amplitude to simulate EEG-waves. The DSP32C is capable of continuously processing spikes at 183.106 Hz. In addition to real-time sorting the DSP32C also performs a running average of the spikes sorted into each class and transfers data to the host computer. The ability of the system to analyse burst of activity is determined by the FIFO memory buffer (2048 samples, or 32.768 ms at 62.5 kHz sampling rate). Adding a 50 Hz sine wave discrimination worked correctly with sine wave amplitudes of up to 2.5 times that of the smallest spike. Combining spikes with noise revealed errors of inclusion and/or exclusion of less than 0.1% provided the models spikes were determined from noiseless spikes and the spike threshold was set above the noise peak level. When noisy spikes were used to define model spikes about 4% of the smallest amplitude spikes (signal to noise ratio 3.3) were incorrectly classified. For higher amplitude spikes (signal to noise ratio > or = 5) the classification error was on average less than 1%. The artificial patterns used for performance testing are exactly defined and could be used to standardize the comparison between different sorting techniques.

Electroencephalography

Fractal dimensions of short EEG time series in humans.

Fractal dimensions has been proposed as a useful measure for the characterisation of electrophysiological time series. But one of the problems of this approach, is the difficulty to record time series long enough of determine the 'real' fractal dimension. Nevertheless it is possible to calculate fractal dimensions for very short data-segments. Using time series of different length it is possible to show, that there is a monotoneous relation between fractal dimension and the number of data-points. This relation could be further interpreted with the help of an extrapolation scheme. In addition this effect is also seen with surrogate data, generated from that signal. We conclude that it is feasible to use fractal dimension as a tool to characterise the complexity for short electroencephalographic (EEG) time series, but it is not possible to decide whether the brain is a chaotic system or not.

Electroencephalography