PubMed HealthSearch

PubMed · 8645689

Labial sensory function following sagittal split osteotomy.

Abstract

A retrospective assessment of labial sensory function following sagittal split osteotomy was undertaken by a combination of record analysis, postal questionnaire and objective sensory testing. Case records for 90 sides operated upon by a single consultant surgeon between 1979 and 1992 identified a prevalence of persisting sensory changed at 2 years of 6.7%. A higher incidence of sensory change was seen in patients treated with intermaxillary fixation/upper border wires than those managed with buccal monocortical miniplates. Postal questionnaire returns for 67 consultant operated sides identified a higher incidence of sensory change than recorded in the notes. 5.9% had long term persisting anaesthesia. Another 28% had more variable subtle sensory impairment. A similar relation to method of fixation was seen. An association between duration of temporary sensory change and magnitude of forward mandibular advance was noted. Objective sensory testing validated the subjectively reported sensory status but also identified many patients self-assessed as normal had some undetected sensory impairment. Possible mechanisms for the above findings and implications for clinical practice are presented.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C A Pratt, H Tippett, J D Barnard, D J Birnie. 1996. Labial sensory function following sagittal split osteotomy.. https://doi.org/10.1016/s0266-4356(96)90141-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Anterior junctional plate in the cervical spine.

STUDY DESIGN: This study introduces a useful plating technique for complex reconstructions of the anterior cervical spine. OBJECTIVE: To provide a short-segment-buttressing technique for the stabilization of long anterior fusion constructs in the cervical spine while avoiding the potential morbidity and risks associated with long-segment anterior cervical plating. SUMMARY OF BACKGROUND DATA: Anterior fibular or iliac crest strut grafts are at risk of dislodging when used after multisegment (> 3 vertebrae) corpectomy in various spinal disorders. Long-segment anterior cervical plates have been used to reduce the incidence of graft displacement and migration but have been shown to increase risk for early failure because of screw dislodgement. METHODS: Eleven patients with cervical myelopathy underwent a multilevel (average 3.36 levels) corpectomy followed by the placement of a fibular or iliac crest strut graft. An anterior short-segment locking or buttress plate was then placed in the vertebral body, either inferior or superior to the seated graft, depending on the ease of insertion and quality of the host bone. Posterior segmental fixation was performed in all patients during the same procedure. The average follow-up was 30.8 months (range, 25-36 months). RESULTS: No incidence of plate or graft migration (anteroposterior plane) or dislodgement was reported in this series. One graft fracture occurred secondary to the placement of a intragraft screw through an anterior junctional plate. No patients experienced clinical morbidity related to the junctional plate. Neurovascular complications and wound complications were not encountered in any of these patients. All had an improvement in their neurologic symptoms, and 10 of the 11 patients had fusion documented on plain radiographs. CONCLUSIONS: The use of a junctional plate anteriorly along with posterior segmental fixation and fusion may prevent or decrease the incidence of graft and internal fixation dislodgement after a long-segment cervical reconstruction procedure.

Bone Plates

Safe lateral-mass screw lengths in the Roy-Camille and Magerl techniques. An anatomic study.

STUDY DESIGN: Investigation of the mean safe lateral-mass screw lengths in the Roy-Camille and Magerl screw techniques in cadaveric cervical specimens. OBJECTIVES: To report the mean screw path length and to evaluate the relation of the screw trajectory to the nerve root in the Roy-Camille and Magerl screw techniques. SUMMARY OF BACKGROUND DATA: Potential injury to the cervical nerve root caused by too long a screw remains a major concern. Few studies regarding proper screw length and its relation to the adjacent nerve root are available. METHODS: Fourteen cervical spines were used for this study. Each lateral mass from C3 to C7 was drilled according to the techniques described by Roy-Camille (right side) and Magerl (left side). The cervical spines were harvested from the cadavers, and the anterior aspect of the lateral mass and spinal nerve were exposed. The screw path length between the dorsal and ventral cortices of the lateral mass were measured. An additional measurement was taken from the ventral aspect of the lateral mass to the nerve root along the screw path. RESULTS: The mean screw path length in the Roy-Camille technique decreased consistently from C3 (15.7 +/- 1.7 mm) to C7 (11.3 +/- 0.8 mm). The mean distance from the ventral cortex to the nerve root ranged from 1.2 to 2.3 mm, and the smallest value was at C7. The mean screw path length in the Magerl technique also decreased from cephelad to caudal, with a range of 15-16 mm at C3-C6 and a mean value of 13.8 mm at C7. CONCLUSIONS: A safe screw length is 14-15 mm in the Roy-Camille technique and 15-16 mm in the Magerl technique at C3-C6. A short screw may be used at C7 if desired.

Bone Plates

Postlaminectomy cervical dislocation in von Recklinghausen's disease. A case report.

STUDY DESIGN: A case of a 9-year-old girl with von Recklinghausen's disease who has acute tetraparesis caused by a complete dislocation of C6-C7 after a cervical laminectomy performed at another hospital. OBJECTIVES: To demonstrate the treatment difficulties of cervical spine abnormality associated with neurofibromatosis. SUMMARY OF BACKGROUND DATA: Craig and Govender have reported cases of neurofibromatosis of the cervical spine (1992). METHODS: The patient underwent emergency surgery starting with a posterior release of the articular facets and with the positioning of two Roy-Camille plates. The dislocation of C6-C7 was reduced by an anterior approach. Finally the Roy-Camille plates were removed, a plate was implanted posteriorly at the C6 and C7 joints, and a posterior cable was positioned around the C2-C3 posterior arches. RESULTS: More than 4.5 years after surgery, the patient's neurologic condition remains satisfactory. She can walk and run and has no sphincter disorders. CONCLUSIONS: The results underline the importance of simultaneous anterior and posterior surgical approaches in this disease.

Bone Plates