PubMed HealthSearch

PubMed · 8649898

Speaking tubes for bedside use.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Cantrell. 1996. Speaking tubes for bedside use.. https://doi.org/10.1016/s0194-5998(96)70238-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimizing MRI signal-to-noise ratio for quadrature unmatched RF coils: two preamplifiers are better than one.

Using separate preamplifiers for the two outputs of a quadrature receive coil (and then combining the preamplifier outputs in a quadrature hybrid) provides a better signal-to-noise ratio (SNR) than is obtained by directly combining the quadrature outputs in a hybrid followed by a single preamplifier. The advantage of the two-preamplifier configuration increases when the body coil impedance changes and is no longer matched to 50 ohms. Using 0.4 dB noise figure preamplifiers, theory predicts 1.53, 0.42, 0, 0.42, and 1.53 dB SNR advantage of the two-preamplifier configuration over the one-preamplifier arrangement at body coil impedances of 12.5, 25, 50, 100, and 200 ohms, respectively. Experimental hot/cold resistor noise figure measurements indicate 2.86, 0.65, 0.36, 0.83, and 1.40 dB noise figure advantage for the two preamplifier configuration relative to the one-preamplifier configuration at those impedances. Empirical gains larger than theoretically calculated are attributable to insertion losses of various circuit elements, such as the quadrature hybrid, for the one-preamplifier configuration.

Amplifiers, Electronic

Maximizing signal-to-noise ratio in the presence of coil coupling.

Crosstalk due to coupling produces noise correlation between receiver coils. It has been stated that this correlation reduces the signal-to-noise ratio obtainable from combining signals from the coils. In this paper, it is shown that the effects of crosstalk on the signal-to-noise ratio may in theory be eliminated by properly combining signals. Equations are derived which show how the signals from two coils should be combined in the presence of crosstalk in order to obtain the same signal-to-noise ratio as in an ideal case of no crosstalk. The deviation from optimum signal-to-noise ratio due to imperfect circuits and amplifiers is discussed. An experimental technique for achieving the proper combination of signals is presented.

Amplifiers, Electronic

Characteristics of fasting and fed myoelectric activity in rat small intestine: evaluation by computer analysis.

Evaluation of gastrointestinal myoelectric activity has been limited by the assessment techniques and the complexity of the recorded myoelectric signal. Commonly, myoelectric activity is evaluated as motor patterns, which only gives a semiquantitative measure of myoelectric events within the bowel wall. Using myoelectric recordings from the proximal small intestine in rats, a computerized system for acquisition, storage, display and calculation of characteristics for the myoelectric activity was developed. The software was tested in myoelectric recordings from nine rats in fasting and fed states. All migrating myoelectric complexes (MMCs) during fasting and fed myoelectric patterns were recognized in both digital and analog recordings. Reproduction of myoelectric recordings by the computerized system was indistinguishable from that of the analog system. Employing an appropriate cut-off trigger level and a high sampling frequency, spike potentials were recorded in the proximal jejunum with 0.4 (0.3-0.5) spikes 10 s-1 during phase 1 of MMC, 19.5 (15.1-23.9) (P < 0.001) during phase 2, and 103.8 (97.2-110.5) (P < 0.001) during phase 3. In fasted state, MMCs were most frequent in the proximal jejunum whereas fewer were found in the duodenum and distal jejunum. To achieve stable values for MMC cycle length at least four MMCs had to be calculated. After feeding in phase 1, the myoelectric activity increased to 23.8 (13.6-33.9) spikes 10 s-1 (P < 0.001), whereafter the spiking activity decreased over a period of 2 h until a fasting motor pattern was resumed. It is concluded that computerized technology enables evaluation not only of myoelectric patterns, but also of spiking activity per time unit, i.e. the intensity of myoelectric activity in the gut.

Amplifiers, Electronic