PubMed HealthSearch

PubMed · 8666463

Does resin based dentine bonding work?

Abstract

Since Buonocore, in the mid 1950s, introduced enamel etching to be used to bond resinous restorations to enamel, different resin based bonding procedures have continuously found their way into dental practise. Today, dentists bond materials not only to enamel, but also to dentine. Up until recently, the clinical success with dentine bonding agents had been unreliable at best, and many clinicians had become sceptical as to whether it would ever be possible to bond to dentine. In this paper, some of the important break-throughs in the field of dentinal adhesives are reviewed in an attempt to throw some light on the question, does resin based dentine bonding work? The technical procedure used to optimise dentine bonding is reviewed, emphasising the significance of etching dentine, placing the primer on a slightly moist dentine surface, avoiding oxygen inhibition of the bonding resin, and maximising the degree of cure. In addition, emphasis is also placed on the significance of variations in dentine structure, and how sclerotic dentine may make dentine bonding less efficient. The conclusion of the entire review is that although significant improvements have been made in the field of dentine bonding during the last few years, it is still too early to conclude that dentine bonding will survive several years of clinical service.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K J Söderholm. 1995. Does resin based dentine bonding work?. https://pubmed.ncbi.nlm.nih.gov/8666463/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Epoxy-embedded versus nonembedded TEM examination of the resin-dentin interface.

When transmission electron microscopy (TEM) is used to evaluate resin-dentin interface specimens for completeness of hybridization, the epoxy resin embedding medium that normally facilitates ultrathin sectioning may produce a secondary or artifactual hybrid layer. This secondary hybrid layer, composed of epoxy resin rather than adhesive resin, may fill the pores that remain as evidence of incomplete resin infiltration, obscuring the fact that they ever existed. In this study, resin-dentin interfaces produced by two dentin adhesive systems, Optibond (OPTI, Kerr) and Scotchbond Multi-Purpose (SBMP, 3M), were comparatively investigated by TEM in epoxy-embedded and nonembedded nondemineralized sections. The hypothesis advanced was that no difference in ultramorphology of the hybrid layer would result from either specimen preparation method. The two adhesive systems were applied to four mid-coronal dentin disks per manufacturer's instructions. One half of each sample was processed following common procedures for TEM sample preparation with epoxy embedding, whereas the other half was not embedded but instead immersed in hexamethyldisilazane (HMDS), dried and mounted so that it protruded from a base of cold-cure acrylic resin. Each sample was then sectioned using a diamond knife in an ultramicrotome. With either means of preparation, a hybrid layer with a relatively uniform electron density and a loose collagen fibril arrangement with electron lucent interfibrillar channels was formed by OPTI. At the base of the hybrid layer, collagen fibrils were anchored in the underlying unaffected dentin, and no microporosities or gaps were observed. Similarly, whether SBMP was embedded or nonembedded, it was found to have a hybrid layer of variable electron density and an electron dense phase localized at the surface of the hybrid layer. No porosities were evident at the base of the hybrid layer. Thus, with either of the two adhesive systems, no ultrastructural difference in hybrid layer formation was observed between epoxy-embedded and nonembedded sections, and no direct evidence of ineffective resin-infiltration of the demineralized collagen scaffold was found.

Acid Etching, Dental

Preliminary results of a multicenter study evaluating a chemically enhanced surface for machined commercially pure titanium implants.

PURPOSE: This report presents the preliminary results of a prospective multicenter study to evaluate the efficacy of a chemically etched pure titanium surface on screw-type dental implants. MATERIAL AND METHODS: The results of 147 implants placed in 75 patients were evaluated and followed for up to 3 years, using clinical and radiographic examinations. The implants were inserted to support single crowns, overdentures, and fixed prostheses, as dictated by the individual patient's need. RESULTS: Of the 147 implants placed, 5 were lost and the remaining implants were followed throughout, to the end of the study period. Crestal bone levels adjacent to each implant were monitored and the amount of total bone loss was calculated. Clinically healthy peri-implant gingival tissues were observed on 95% of the implants, whereas 88.3% demonstrated no bleeding on probing and no recession during the follow-up period. According to the criteria used in this study, the total success rate was calculated to be 96.6%.

Acid Etching, Dental

Alternative method of conservative esthetic treatment for gingival recession.

The health and appearance of gingival tissue play an essential role in esthetics. The esthetic function of the tissue is enhanced when it frames the restoration. With gingival recession, the effect of natural gingiva is created with pink composites or ceramics on the cervical part of the crown, as described in this clinical report. This goal depends on the absence of adverse effects on the color, shape, and health of the surrounding tissue. The new composites are more color stable and wear resistant, and the latest generation of dental bonding agents allows the bonding of composites to dentin, various metals, and porcelain. The application of soft-tissue colored composite on dentin cementum, enamel, or porcelain is a good solution for correcting gingival recessions.

Acid Etching, Dental