PubMed Health⌕ Search

PubMed · 8668785

Acute and chronic stroke: navigated spin-echo diffusion-weighted MR imaging.

Abstract

PURPOSE: The authors evaluated a phase-navigated spin-echo (SE) motion-correction sequence for use at diffusion-weighted (DW) magnetic resonance (MR) imaging after cerebral infarction. MATERIALS AND METHODS: Twenty-nine patients underwent 32 conventional T2-weighted fast SE and SE DW imaging after stroke (n=25), transient ischemic attack (n=3), or reversible ischemic neurologic deficit (n=1). Imaging was performed in a standard head holder with standard padding. Apparent diffusion coefficient (ADC) maps were constructed. RESULTS: DW images depicted high signal intensity compatible with localization of the ischemic symptoms in all cases. Lesions were depicted more clearly on DW than on T2-weighted images. On DW images, acute infarct ADC values were uniformly low (mean, 0.401x10(-5) cm2/sec =+/- 0.143 [standard deviation]) compared with control ADC values (mean, 0.754x10(-5) cm2/sec +/- 0.201). ADC values of chronic infarcts were supranormal (mean, 1.591x10(-5) cm2/sec +/- 0.840) compared with control values (mean, 0.788x10(-5) cm2/sec +/- 0.166). DW imaging did not show a change after transient ischemic attack. with reversible ischemic neurologic deficit, however, hyperintensity on DW images and low ADC resolved after symptoms abated. CONCLUSION: Clinical phase-navigated SE DW imaging improved early diagnosis of stroke and helped differentiate acute from chronic stroke. Changes on DW images are reversed after symptoms resolve.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M P Marks, A de Crespigny, D Lentz, D R Enzmann, G W Albers, M E Moseley. 1996. Acute and chronic stroke: navigated spin-echo diffusion-weighted MR imaging.. https://doi.org/10.1148/radiology.199.2.8668785

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗