PubMed Health⌕ Search

PubMed · 8705181

Effective doses for coronary angiography.

Abstract

A detailed study of dose data has been made for 100 coronary angiography examinations performed on a digital X-ray unit. Dose-area product (DAP) data have been analysed in terms of fluoroscopy and radiography for different projections. Projections patterns were similar for all cardiologists studied and the contribution to DAP from fluoroscopy was 32%. Data for 10 patients, selected because the percentage contributions to DAP from fluoroscopy and radiography were similar to the mean for the group, were used to derive conversion factors from DAP to effective dose. The mean DAP was 14 Gy cm2 and the effective dose 3.1 mSv. Conversion factors, based on the same protocol, were derived for a range of tube potentials and filtrations for use in estimation of effective doses with other units.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K C Leung, C J Martin. 1996. Effective doses for coronary angiography.. https://doi.org/10.1259/0007-1285-69-821-426

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Repeat right transradial percutaneous coronary intervention in a patient with dextrocardia: the right approach to the right-sided heart.

Dextrocardia (DC) is a rare cardiac condition in which the cardiac location, as well as apex, is rightwardly displaced. As the incidence of atherosclerotic disease is similar to that of the general population, there have been few reports of percutaneous coronary interventions (PCIs) in these patients. Proposed technical strategies for successful angiography and PCI in DC include counter-directional torquing of the catheter, as well as right-left mirror-image inversion angiographic views. All previous reports of DC PCIs have been via transfemoral access.We present a case of successful repeat transradial PCI in a patient with DC. This is first report of transradial coronary angiography, PCI, or repeat PCI in a DC patient. A literature review of technical considerations, including our own recommendations for guide catheter selection, are discussed. We also review the anatomic variations and epidemiology of DC. Although access complications for transradial PCI is known to be lower than that of the transfemoral approach, challenges in technique and concern of repeat access have limited the popularity of the former. Our report demonstrates the safety and feasibility of transradial angiography, PCI, and even repeat PCI, in the rare patient with DC.

Coronary Angiography↗