PubMed HealthSearch

PubMed · 8706888

Surface display on staphylococci: a comparative study.

Abstract

Two different host-vector expression systems, designed for cell surface display of heterologous receptors on Staphylococcus xylosus and Staphylococcus carnosus, respectively, were compared for the surface display of four variants of a 101 amino acid region derived from the G glycoprotein of human respiratory syncytial virus (RSV). Surface localization of the different chimeric receptors was evaluated by a colorimetric assay and by fluorescence-activated cell sorting. It was concluded that the S. carnosus system was better both in the ability to translocate inefficiently secreted peptides and in the number of exposed hybrid receptors. The potential use of the described staphylococci as live bacterial vaccine vehicles or alternatives to filamentous phages for surface display of protein libraries is discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Robert, P Samuelson, C Andréoni, T Bächi, M Uhlén, H Binz, T N Nguyen, S Ståhl. 1996-07-29. Surface display on staphylococci: a comparative study.. https://doi.org/10.1016/0014-5793(96)00684-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Experimental and model investigations of bleaching and saturation of fluorescence in flow cytometry.

We investigated the fluorescence emission from three fluorophores commonly used for labeling cells in flow cytometry. We have demonstrated that the fluorescence emission from cells labeled with fluorescein-isothiocyanate (FITC), phycoerythrin (PE), and allophycocyanin (APC) is considerably saturated and bleached in standard flow cytometric conditions. Therefore, for optimization of fluorescence detection in a flow cytometer, it is important to know the emission kinetics in detail. We made a mathematical model of the optical processes involved: absorption, fluorescence emission, nonradiative decay, photodestruction, and triplet state occupation. The validity of the model was experimentally tested with a set of averaged fluorescence pulses, measured in a large range of intensities and illumination times. The fluorescence of APC could be completely described by the model and produced the following rate constants: photodestruction rate kb1 = 6 x 10(3) s(-1), triplet state population rate k12 = 2 x 10(5) s(-1), and depopulation rate k20 = 5 x 10(4) s(-1). The fluorescence kinetics of FITC- and PE-labeled cells could not be fitted with only three parameters over the entire range, indicating that other optical processes are involved. We used the model to determine the sensitivity of our flow cytometer and to calculate the optimum conditions for the detection of APC. The results show that in principle a single APC molecule on a cell can be detected in the presence of background, i.e., autofluorescence and Raman scattering by water.

Flow Cytometry