PubMed Health⌕ Search

PubMed · 8730191

Cervical spondylosis: three-dimensional gradient-echo MR with magnetization transfer.

Abstract

PURPOSE: To compare a three-dimensional Fourier transform (3DFT) gradient-echo pulse sequence with magnetization transfer at a short echo time against standard 3DFT gradient-echo technique in the evaluation of cervical spondylosis, specifically addressing the effects of motion and susceptibility artifacts on the dimensions of the neural foramina and contrast at the cerebrospinal fluid (CSF)-spinal cord interface. METHODS: Ten patients with clinically suspected cervical spondylosis were examined with axial MR imaging using both our standard 3DFT gradient-echo sequence and a 3DFT gradient-echo sequence with a short echo time plus magnetization transfer. Two neuroradiologists measured the transverse dimensions of 22 diseased neural foramina and graded the contrast at the CSF-spinal cord interface. RESULTS: Sixteen of 22 affected neural foramina were larger in the transverse dimension when the magnetization transfer technique was used than when the standard 3DFT gradient-echo sequence was used. In 9 of 10 patients superior contrast was seen at the CSF-spinal cord interface on images obtained with the magnetization transfer technique. CONCLUSIONS: In the cervical spine, 3DFT gradient-echo imaging with magnetization transfer improves contrast and sharpness of the CSF-spinal cord interface at short echo times. This results in less exaggeration of the neural foraminal stenosis as compared with that seen with standard 3DFT gradient-echo techniques owing to the diminished effects of motion and susceptibility artifacts.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E R Melhem, M L Benson, N J Beauchamp, R R Lee. 1996. Cervical spondylosis: three-dimensional gradient-echo MR with magnetization transfer.. https://pubmed.ncbi.nlm.nih.gov/8730191/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Cerebrospinal fluid dissecting into spinal epidural space after lumbar puncture causing cauda equina syndrome: review of literature and illustrative case.

OBJECTS: We report a case of epidural cerebrospinal fluid (CSF) leak after lumbar puncture caused by CSF dissecting into the spinal epidural space. The incidence of this phenomenon may be higher than suspected, although most cases may remain asymptomatic. MATERIALS AND METHODS: A 4-year-old girl with new-onset seizure underwent a diagnostic lumbar puncture, the results of which were normal; 3 h later, she began experiencing severe low-pressure headaches and lower back pain, bilateral lower extremity weakness, numbness, and pain, and urinary retention when upright. Spinal MRI demonstrated extensive epidural CSF collection posterior to the thecal sac extending from the cervicothoracic junction to the sacrum. After 48 h in the supine position and gradual mobilization, the patient had complete resolution of symptoms and no neurological sequelae. CONCLUSION: Patients usually recover without any neurological deficits after conservative treatment. Prone or lateral decubitus positioning immediately after lumbar puncture may decrease the incidence of this phenomenon.

Cerebrospinal Fluid↗