PubMed HealthSearch

PubMed · 8733638

A keyboard for "Daubert".

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N M Hadler. 1996. A keyboard for "Daubert".. https://doi.org/10.1097/00043764-199605000-00007

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

New system for linear accelerator radiosurgery with a gantry-mounted video camera.

PURPOSE: We developed a positioning method that does not depend on the positioning mechanism originally annexed to the linac and investigated the positioning errors of the system. METHODS AND MATERIALS: A small video camera was placed at a location optically identical to the linac x-ray source. A target pointer comprising a convex lens and bull's eye was attached to the arc of the Leksell stereotactic system so that the lens would form a virtual image of the bull's eye (virtual target) at the position of the center of the arc. The linac gantry and target pointer were placed at the side and top to adjust the arc center to the isocenter by referring the virtual target. Coincidence of the target and the isocenter could be confirmed in any combination of the couch and gantry rotation. In order to evaluate the accuracy of the positioning, a tungsten ball was attached to the stereotactic frame as a simulated target, which was repeatedly localized and repositioned to estimate the magnitude of the error. The center of the circular field defined by the collimator was marked on the film. RESULTS: The differences between the marked centers of the circular field and the centers of the shadow of the simulated target were less than 0.3 mm.

Computer Terminals

Video display terminals: risk of electromagnetic radiation.

BACKGROUND: Technologic advances have led to increased use of computers at home and in the workplace. It is estimated that more than 100 million workers in the United States and Canada will be using computers daily by the year 2000. Anecdotal reports have suggested a link between video display terminals (VDTs) and disease. This has generated much concern about whether electromagnetic radiation (EMR) emitted by VDTs cause illness among users. METHODS: We reviewed pertinent articles in the literature. RESULTS: Several studies have addressed the role of VDTs in disease causation, specifically whether EMR causes skin or ocular disease or obstetric complications. The data reviewed were inconsistent or methodically flawed. Therefore, a definitive conclusion cannot be drawn to support the hypothesis that EMR produced by VDTs causes disease. CONCLUSIONS: We believe continued research should be done to further define and elucidate the risk of EMR produced by VDTs.

Computer Terminals

Performance of a video-image-subtraction-based patient positioning system.

PURPOSE: We have developed and tested an interactive video system that utilizes image subtraction techniques to enable high precision patient repositioning using surface features. We report quantitative measurements of system performance characteristics. METHODS AND MATERIALS: Video images can provide a high precision, low cost measure of patient position. Image subtraction techniques enable one to incorporate detailed information contained in the image of a carefully verified reference position into real-time images. We have developed a system using video cameras providing orthogonal images of the treatment setup. The images are acquired, processed and viewed using an inexpensive frame grabber and a PC. The subtraction images provide the interactive guidance needed to quickly and accurately place a patient in the same position for each treatment session. We describe the design and implementation of our system, and its quantitative performance, using images both to measure changes in position, and to achieve accurate setup reproducibility. RESULTS: Under clinical conditions (60 cm field of view, 3.6 m object distance), the position of static, high contrast objects could be measured with a resolution of 0.04 mm (rms) in each of two dimensions. The two-dimensional position could be reproduced using the real-time image display with a resolution of 0.15 mm (rms). Two-dimensional measurement resolution of the head of a patient undergoing treatment for head and neck cancer was 0.1 mm (rms), using a lateral view, measuring the variation in position of the nose and the ear over the course of a single radiation treatment. Three-dimensional repositioning accuracy of the head of a healthy volunteer using orthogonal camera views was less than 0.7 mm (systematic error) with an rms variation of 1.2 mm. Setup adjustments based on the video images were typically performed within a few minutes. The higher precision achieved using the system to measure objects than to reposition them suggests that the variability in repositioning is dominated by the ability of the therapist to make small, controlled changes in the position of the patient. CONCLUSION: Using affordable, off-the-shelf technology, we have developed a patient positioning system that achieves repositioning accuracy normally associated with fractionated stereotactic systems. The technique provides real-time guidance and can be used to easily and quickly correct patient setup before every treatment, thus significantly reducing overall random positioning error. This improved positioning capability provides the precision required to realize the potential gains of conformal radiotherapy.

Computer Terminals