PubMed Health⌕ Search

PubMed · 8743763

Transvenous defibrillation lead systems.

Abstract

The use of the implantable cardioverter defibrillator has grown dramatically over the past 10 years. One of the major advances in defibrillation technology is the development of transvenous lead systems. Compared with traditional epicardial lead systems, transvenous defibrillation leads reduce perioperative mortality, hospitalization, and costs. Transvenous lead systems provide reliable sensing of ventricular tachyarrhythmias, although redetection of ventricular fibrillation can be prolonged, especially with integrated lead systems. Both ramp and burst adaptive pacing are equally effective for the termination of ventricular tachycardia and are successful in up to 90% of spontaneous events. Defibrillation thresholds are higher with transvenous leads than with epicardial patches. These thresholds are reduced with the use of multiple transvenous leads, subcutaneous patches, or with reversing shock polarity. However, the development of biphasic waveforms has made the largest impact on the efficacy of these lead systems, allowing dual coil transvenous systems to be effective in about 90% of patients. Defibrillation efficacy is further enhanced and implantation simplified by the incorporation of an active pulse generator located in the left pectoral region. Active pectoral pulse generators with biphasic waveforms will be the primary lead system for new implants.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M R Gold, S R Shorofsky. 1996. Transvenous defibrillation lead systems.. https://doi.org/10.1111/j.1540-8167.1996.tb00564.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Does the rate of inappropriate therapy differ in implantable cardioverter-defibrillators from different manufacturers?

OBJECTIVE: We conducted this study to compare the rate of >/=1 inappropriate therapy between ICDs from two manufacturers which use different discriminatory protocols. METHOD: One hundred sixty two patients (mean age 58 +/- 13 years, 126 male) who received ICDs between January 2001 and 2005 were included in the study. Clinical, electrocardiographic, and ICD stored data and electrograms were collected and analyzed. Immediately after implantation all the detection and discrimination criteria were activated with the nominal values in order to compare the two discriminatory protocols under the default manufacturer's settings. RESULTS: During the follow up period of 14.3 +/- 10 months, 49 (30%) patients received >/=1 inappropriate ICD therapy. The rate of >/=1 inappropriate ICD therapy in manufacturer A and B ICDs was 26% (n = 29) and 41% (n = 20), respectively. Comparing the rate of >/=1 inappropriate ICD therapy between the two groups by Kaplan-Meier analysis and the log rank test resulted in P = 0.04. CONCLUSION: Having all discriminatory variables activated with the nominal values, discriminatory performance differs between the two manufacturers. Further larger-scale studies are warranted to prospectively compare the performance of various available ICDs' discriminatory protocols, and define the optimum combination of discriminators in each ICD to decrease the rate of inappropriate therapy.

Defibrillators, Implantable↗

Cardiac pacemakers and implantable cardioverter defibrillators: in vitro magnetic resonance imaging evaluation at 1.5-tesla.

RATIONALE AND OBJECTIVES: To evaluate the effect of Magnetic Resonance Imaging (MRI) performed at 1.5-Tesla on current generation pacemakers and ICDs to identify safe parameters for MRI examinations. METHODS: Pacemakers (Identity ADx XL DR+ 5386 and Identity ADx DR + 5380 generators; 1688T/52-cm atrial and ventricular leads) and ICDs (Atlas + V-243, Epic + V-236, and Epic + HF V-350 generators; Riata 1581/65-cm and QuickSite 1056K/75-cm leads; St. Jude Medical, Sylmar, California, USA) were evaluated for magnetic field interactions. MRI-related heating was assessed using various levels of RF power (SARs) and conditions that included scans on different body regions. Functional aspects of the devices were evaluated immediately before and after MRI procedures utilizing nine different pulse sequences. Induced currents were measured using a custom built system. RESULTS: Magnetic field interactions will not create a hazard for these pacemakers and ICDs. All scans of the "head" and "lumbar" regions resulted in temperature changes < or =0.5 degrees C at SARs ranging from 2.0 to 3.0-W/kg. For the "chest" area, temperature increases ranged from 0.4 degrees C to 3.6 degrees C at an SAR of 2.0-W/kg. No memory corruption, hardware changes, or changes in device parameters were seen. Magnetic field gradients have a low likelihood of inducing currents that would stimulate the heart. CONCLUSIONS: No hazardous magnetic field interactions or physiologically significant heating occurred for certain conditions. There was no permanent effect on device function. By following specific conditions, these pacemakers and ICDs may be safe for patients scanned at 1.5-Tesla.

Defibrillators, Implantable↗