PubMed HealthSearch

PubMed · 8747696

Perspectives on thromboelastography.

Abstract

The knowledge of these sources of error together with strict methodology assure reliable results and avoid what some authors consider limitations of the test. These so-called limitations are actually due to incomplete information or insufficient experience. It is our opinion that the key for success when using TEG is to use the test in those cases for which it has been indicated. Also, the fact that TEG is a global test of coagulation should be kept in mind and therefore the need for additional hemostatic tests should be evaluated when applicable (Fig.3). According to this review, the established applications of TEG are as follows: (1) detection of hypercoagulable states, particularly in the postoperative period and for patients with malignancies; (2) management of patients who are administered intravenous heparin; (3) monitoring the coagulation state during liver transplantation; (4) monitoring the coagulation state and management of patients during cardiopulmonary bypass; and (5) diagnosis and treatment of hematologic dysfunctions, particularly hemophilia. Management of patients under warfarin administration, as well as monitoring of the adjustment of subcutaneous heparin prophylaxis in several surgical procedures, should probably belong to this list, but further studies are needed to confirm these roles. Used by experienced hands, TEG is a valuable hemostatic test, the future of which is already present.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J A Caprini, C I Traverso, J I Arcelus. 1995. Perspectives on thromboelastography.. https://doi.org/10.1055/s-0032-1313629

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts

Does change in skin perfusion provide a good index to monitor the sympathetic response to a noxious stimulus in preterm newborns?

Skin perfusion was measured using laser Doppler fluximetry (LDF) in 16 preterm babies undergoing a standardised heel prick procedure. Although there was a significant reduction in skin blood flow following the heel prick, this was variable and dependent on basal skin blood flow. This, together with loss of data due to movement artefact, makes this technique unreliable in quantifying the sympathetic response to a noxious stimulus in preterm infants.

Artifacts