[Simplified vasovasostomy].
Abstract
OBJECTIVES: A simplified technique to repair seminal duct obstruction is described. METHODS: Optical magnification, a channeled instrument as a suture guide that we have developed and fibrin glue are utilized. RESULTS: This technique is safe, reduces operating time and achieves similar results as with a surgical microscope. CONCLUSIONS: This technique facilitates repair of small caliber structures, reduces the operating time and does not require large microscopic systems.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
J M Saladié Roig, J Comet Batlle, J Areal Calama, L Cecchini Rosell, J Uría González-Tova. 1996. [Simplified vasovasostomy].. https://pubmed.ncbi.nlm.nih.gov/8766088/