PubMed HealthSearch

PubMed · 8776477

Limitations on position coding imposed by undersampling and univariance.

Abstract

Position judgements, which are exquisitely precise in the fovea, are markedly degraded in the periphery. In a recent article [Hess & Field (1993) Vision Research, 33, 2663-2670] argue that the poor representation of positional information in peripheral vision is a consequence of uncalibrated spatial disorder of cortical connections rather than due to undersampling of the retinal image. Specifically, Hess and Field argued that if positional uncertainty is due to undersampling, then because of univariance, there should be an associated contrast uncertainty. In this report we show that the univariance model is limited in its generality since: (1) the Hess and Field data in which contrast and position discrimination are decoupled do not preclude undersampling with large univariant filters: (2) aliasing can decouple position from contrast; (3) undersampling or noise at a second stage of processing can lead to selective losses of position information without any degradation of contrast information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D M Levi, S A Klein. 1996. Limitations on position coding imposed by undersampling and univariance.. https://doi.org/10.1016/0042-6989(95)00264-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Moving segments region of interest attenuator for x-ray fluoroscopy.

Region of interest (ROI) imaging has previously been proposed as a means of reducing x-ray fluoroscopy radiation dose. Previous ROI attenuators made of partially attenuating metal plates change beam quality, which may lead to uncertainty in image restoration procedures. The design and construction of a prototype moving segments ROI attenuator (MS-ROI), which maintains beam quality across the whole field of view is described. The x-ray beam intensity is halved by 36 lead segments which are rapidly rotated between the x-ray tube and patient, with a central hole projecting a circular ROI at full intensity. Image processing techniques with automatic detection of the ROI boundary were used to homogenize image brightness across the whole image. Images restored using these techniques were judged to be visually acceptable, with a good match between pixel values inside and outside the ROI. Image contrast within the ROI was improved by 18% due to reduced scatter and veiling glare from the periphery. The introduction of the MS-ROI attenuator also results in a 48% increase in statistical noise in the area outside the ROI, with no significant change in object contrast. The patient entrance dose measured using the dose area product (DAP) method was reduced by 53.4% under manual exposure control, with the dose to operators reduced by 48.4% under automatic brightness control. Further work is needed to determine whether the attenuator can be used with pulsed fluoroscopy, and to reduce vibrational effects on the ROI boundary. The MS-ROI attenuator provides a more constant ratio of central-to-peripheral image intensity, and maintains uniform beam quality and image contrast across the whole image in comparison to simple metal plate attenuators.

Contrast Sensitivity

Modulation frequency and orientation tuning of second-order texture mechanisms.

Modulation frequency and orientation tuning of second-order mechanisms underlying the detection of modulation in local spatial-frequency information are assessed by using an oblique-masking paradigm. Stimuli were Gabor-filtered noise patterns in which the local carrier spatial frequency was modulated about an average value of 4.7 cycles per degree (cpd) according to sinusoidal function. Thresholds were determined for spatial-frequency modulated test patterns (0.2 and 0.8 cpd) with fixed vertical carrier and modulation orientations presented alone and in the presence of spatiotemporally superimposed masks. Mask modulation frequency (0.1, 0.2, 0.4, 0.8, or 1.6 cpd), modulation orientation (0 degree, 45 degrees, or 90 degrees relative to vertical), and carrier orientation (18.5 degrees or 90 degrees relative to vertical) were manipulated independently while the mask modulation amplitude remained fixed at 0.25. Manipulating the modulation frequency of the mask revealed some modulation frequency specificity, particularly at lower test modulation frequencies. Spatial-frequency modulated masks produced threshold elevations regardless of the local carrier orientation. However, there was no evidence of threshold elevation when the mask modulation orientation was orthogonal to that of the test pattern. These results suggest a second-order texture mechanism that is tuned to both modulation frequency and modulation orientation but is not selective in terms of the orientation of first-order inputs.

Contrast Sensitivity

Detection improvement in spatially filtered x-ray fluoroscopy image sequences.

The effect of spatial noise-reduction filtering on human observer detection of stationary cylinders mimicking arteries, catheters, and guide wires in x-ray fluoroscopy was investigated in both single image frames and image sequences. Ideal edge-preserving spatial filtering was simulated by filtering of the noise before addition of the target cylinder. This allowed us to separate the effect of edge blurring from those of noise reduction and spatial noise correlation. We used three different center-weighted averagers that reduced pixel noise variance by factors of 0.75, 0.50, and 0.25. As compared with no filtering, the effect of filtering on detection in single images was statistically insignificant. This indicated an adverse effect of spatial noise correlation on detection that countered the effect of noise reduction. By comparison, spatial filtering significantly improved detection in image sequences and yielded potential x-ray dose savings of 26-34%. Comparison of results with two observer models suggested that human observers have an improved detection efficiency in spatially filtered image sequences as compared with white-noise sequences. Pixel noise reduction, a measure commonly used to assess filter performance, overestimated the effect of filtering on detection and was not a good indicator of image quality. We conclude that edge-preserving spatial filtering is more effective in sequences than in single images and that such filtering can be used to improve image quality in noisy image sequences such as x-ray fluoroscopy.

Contrast Sensitivity