PubMed HealthSearch

PubMed · 8776491

Stereopsis from interocular spatial frequency differences is not robust.

Abstract

Based on data obtained using one-dimensional noise patterns, Tyler & Sutter (1979). (Vision Research, 19, 859-865) concluded that stereoscopic tilt can result from an interocular spatial frequency difference in the absence of consistent horizontal disparity. We tested stereopsis using two-dimensional random-dot patterns that were bandpass filtered to contain 1.0 octave bands of spatial frequency with means that differed between the two eyes. With vertical, one-dimensional stimuli we replicated the results of Tyler and Sutter. However, stereoscopic tilt was not perceived based on spatial frequency differences alone when the monocular images contained as little as a +/- 14 deg range of orientation variation. In addition, model simulations demonstrate that the modest steroscopic performance produced by interocular spatial frequency differences in one-dimensional noise patterns are predicted by random disparity correlations at the pattern edges. The observations lead to the conclusion that stereopsis from frequency differences in the absence of pointwise disparity correlations does not reflect a special processing capability of human vision but is an artifact associated with one-dimensional stimuli. As such, it plays no role in steroscopic analysis of the natural environment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D L Halpern, H R Wilson, R Blake. 1996. Stereopsis from interocular spatial frequency differences is not robust.. https://doi.org/10.1016/0042-6989(95)00293-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of display size on disparity scaling from differential perspective and vergence cues.

The present study compared the relative effectiveness of differential perspective and vergence angle manipulations in scaling depth from horizontal disparities. When differential perspective and vergence angle were manipulated together (to simulate a range of different viewing distances from 28 cm to infinity), approximately 35% of the scaling required for complete depth constancy was obtained. When manipulated separately the relative influence of each cue depended crucially on the size of the visual display. Differential perspective was only effective when the display size was sufficiently large (i.e., greater than 20 deg) whereas the influence of vergence angle, although evident at each display size, was greatest in the smaller displays. For each display size the independent effects of the two cues were approximately additive. Perceived size (and two-dimensional spacing of elements) was also affected by manipulations of differential perspective and vergence. These results confirm that both differential perspective and vergence are effective in scaling the perceived two-dimensional size of elements and the perceived depth from horizontal disparities. They also show that the effect of the two cues in combination is approximately equal to the sum of their individual effects.

Convergence, Ocular

Can random-dot stereograms serve as a model for the perception of depth in relation to real three-dimensional objects?

The ability to perceive depth in a random-dot stereogram is a valuable test for the perception of retinal image disparities, whether they arise from the viewing of a stereogram or from the viewing of a real 3-D object. However, a stereogram cannot be regarded as a proper model for the perception of depth in the case of a real 3-D object. This conclusion comes out most clearly in relation to changes in viewing distance. Whereas the viewing of real objects and stereograms both obey the rules of size constancy, this is not the case with depth constancy. With changes in viewing distance, the viewing of real objects obeys the rules of depth constancy. By contrast, the magnitude of the depth intervals in a stereogram are not constant but appear to increase in direct proportion to the increase in viewing distance. In a stereogram these changes in the amplitude of the depth intervals are based on the same mechanisms as those responsible for size constancy.

Convergence, Ocular

Binocular eye movements caused by the perception of three-dimensional structure from motion.

We report that the perception of three-dimensional structure from monocular two-dimensional images changing over time--the kinetic depth effect (KDE)--can evoke binocular eye movements consistent with a three-dimensional percept. We used a monocular KDE stimulus that induced a vivid perception of a rigid three-dimensional sphere rotating in space. The gaze directions of both eyes were measured while observers pursued the motion of a patch on the surface of the perceived sphere as it went through a complete revolution. We found that the eyes converged when the patch was perceived on the front surface of the KDE sphere and diverged when the patch was perceived in the back. The pattern, magnitude and dynamics of binocular eye movements observed in the KDE experiment resembled those obtained when subjects viewed binocularly a light-emitting diode (LED) rotating in space and to the responses obtained with a dynamic stereogram simulating a rotating random dot sphere. Thus, the perception of three-dimensional structure from motion, stereopsis, or motion and stereopsis combined, were effective in guiding binocular eye movements.

Convergence, Ocular