PubMed HealthSearch

PubMed · 879092

Calibration methods for automated hematology instruments.

Abstract

Recent CAP survey data have documented marked improvement in the reproducibility of hematologic tests. The favorable outcome is attributable largely to the widespread use of automated whole-blood analyzers. Calibration variability, however, detracts from this enhanced precision, and there are clear indications that improvement is necessary. Primary calibration methods for hemoglobin, hematocrit and cell counting procedures are presented. The methods of applying these primary calibration methods to automated whole-blood analyzers are delineated. The use of both preserved reference blood and statistical control technics for the identification of calibration loss is described.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P R Gilmer, L J Williams, J A Koepke, B S Bull. 1977. Calibration methods for automated hematology instruments.. https://pubmed.ncbi.nlm.nih.gov/879092/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Oligonucleotide labeling methods. 3. Direct labeling of oligonucleotides employing a novel, non-nucleosidic, 2-aminobutyl-1,3-propanediol backbone.

Novel CE-phosphoramidite (7a-e) and CPG (8a, c, d, e) reagents have been prepared from a unique 2-aminobutyl-1,3-propanediol backbone. The reagents have been used to directly label oligonucleotides with fluorescein, acridine, and biotin via automated DNA synthesis. The versatile 2-aminobutyl-1,3-propanediol backbone allows for labeling at any position (5', internal, and 3') during solid phase oligonucleotide synthesis. Multiple labels can be achieved by repetitive coupling cycles. Furthermore, the 3-carbon atom internucleotide phosphate distance is retained when inserted internally. Using this method, individual oligonucleotides possessing two and three different reporter molecules have been prepared.

Automation

[Routine application of HLA class II oligotyping. Value of automatization].

HLA class II typing by DNA amplification and hybridization with allele-specific oligonucleotides has led to an improvement of the overall typing accuracy. In an attempt to apply this procedure to a large-scale analysis, we sought to implement an automation system using the Biomek 1,000 robotic work-station. This system allows a rapid preparation of many consecutive samples and avoids the risk of human errors. It is now routinely used in several laboratories.

Automation