PubMed Health⌕ Search

PubMed · 8799747

Cardiac assist devices.

Abstract

The two primary goals of mechanical circulatory support are to provide adequate perfusion of the vital organs and to decrease cardiac work. The support of the myocardium is in an effort to cause a reversal of cardiac damage. The recovery process apparently takes place in two stages. Initially, there is a rapid functional recovery of cells in marginally ischemia areas. Then there is a slower process of hypertrophy of normal and recovering myofibers. The process involves the reversal of interstitial and of intercellular myocardial edema in areas of viable myocardium while halting the extension of necrosis into reversibly ischemic areas. It appears that this process is extended from 3 to 5 days, and functional recovery can occur for up to 2 weeks. After a 2-week period, there appears to be little functional recovery of myocardial cells. In autopsy series of nonsurvivors, it appears that most of the patients had suffered from biventricular failure. Biventricular failure appears to be one of the more common complications of the support patient. Right ventricular failure will be attempted to be supported by right ventricular assist devices. The right ventricular assist device, unfortunately, adds a level of complication to the recovery process for the bridge-to-transplant or cardiomyopathy patient. The patients who are involved in support fall into three categories: (1) the bridge-to-transplant patient, (2) the patient recovering from postcardiotomy, and (3) the patient who recovers from an acute myocardial insult. It appears that after 2 weeks the recovery period for all of these groups demonstrates no further functional recovery. The bridge-to-transplant patients usually need to be supported until the transplant occurs. The postcardiotomy patient and the acute myocardial failure patient are the most disappointing support group, since they have a higher morbidity and mortality, and a lower chance of recovery. Salvage rates appear to be in approximately the 25% range in the acute insult category.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A G Hill, R C Groom, N A Burton, E A Lefrak. 1996. Cardiac assist devices.. https://doi.org/10.1097/00004311-199603420-00008

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Hemodynamic evaluation of the posterior ciliary circulation in exfoliation syndrome and exfoliation glaucoma.

BACKGROUND: Previous studies have reported impaired blood flow in the ophthalmic artery (OA) and central retinal artery (CRA) in exfoliation syndrome and exfoliation glaucoma. This study evaluates blood flow at the long and short posterior ciliary arteries (LPCA and SPCA, respectively) in these conditions. METHODS: Consecutively examined candidates for cataract surgery were included. Only one eye (OD) was included in the analyses for consistency. Patients were classified into non-glaucoma and non-exfoliation (controls), primary open angle glaucoma (POAG), exfoliation syndrome and exfoliation glaucoma groups, based on the findings of the OD. Sixty-eight patients (41 males, 60.3%) were included. Color Doppler imaging (CDI) of the nasal and temporal branches of LPCA and SPCA was performed using a 7.5 Mhz probe. The peak systolic velocity (PSV), end diastolic velocity (EDV) and resistivity index (RI) were recorded for the examined vessels. RESULTS: EDV at the LPCA was significantly lower in exfoliation syndrome and glaucoma, compared with controls and POAG respectively. EDV was significantly lower and RI was significantly higher at the SPCA in exfoliation glaucoma, compared with exfoliation, whereas respective differences were statistically not significant between controls and POAG. CONCLUSIONS: The hemodynamic impairment at the LPCA in exfoliation syndrome and glaucoma supports an association between exfoliation and ischemic stress at the anterior ocular segment.

Blood Circulation↗

Assessment and support of the preterm circulation.

There are no clinical outcome data on which to base recommendations on how to assess and support the preterm circulation. Current standards are derived from an assumed proportionality between systemic and organ blood flow and mean blood pressure. Our study of central measures of systemic blood flow suggests preterm haemodynamics are more complex than this. Low systemic blood flow is common in the first 24 h after birth in very preterm babies and is not necessarily reflected by low blood pressure. The causes of this low systemic blood flow are complex but may relate to maladaptation to high extrauterine systemic (and sometimes pulmonary) vascular resistance. After day 1, hypotensive babies are more likely to have normal or high SBF reflecting vasodilatation. Empirically, inotropes that reduce afterload (such as dobutamine) may be more appropriate in the transitional period, while those with more vasoconstrictor actions (such as dopamine) may be more appropriate later on. Defining the haemodynamic in an individual baby needs both blood pressure and echocardiographic measures of systemic blood flow. Research in this area needs to move beyond just demonstrating changes in physiological variables to showing improvements in important clinical outcomes.

Blood Circulation↗

A dose-response curve for the negative bias pressure of an intrathoracic pressure regulator during CPR.

An intrathoracic pressure regulator (ITPR) is a device that can be added to the external end of a tracheal tube to create controlled negative airway pressure between positive pressure ventilations. The resulting downward bias of the airway pressure baseline promotes increased venous return and enhanced circulation during CPR and also during hypovolemic shock. In the present study, we exercised a mathematical model of the human cardiopulmonary system, including airways, lungs, a four chambered heart, great vessels, peripheral vascular beds, and the biomechanics of chest compression and recoil, to determine the relationship between systemic perfusion pressure during CPR and the value of baseline negative airway pressure in an ITPR. Perfusion pressure increases approximately 50% as baseline airway pressure falls from zero to -10 cm H2O. Thereafter perfusion pressure plateaus. Negative bias pressures exceeding -10 cm H2O are not needed in ITPR-CPR.

Blood Circulation↗