[Electrophysiological study].

Abstract

The purpose of an electrophysiological study (EPS) is to determine the mechanism of arrhythmias and to decide the means of therapy for that arrhythmia. The electrode catheters are introduced percutaneously into the atria or ventricle to record the intracardiac electrogram or to stimulate those areas by electrical current. In bradycardia, atrioventricular block and sick sinus syndrome are the good indications of EPS. To determine the indication of pacemaker implantation, recording the block site of atrioventricular block is useful, and sinus node recovery time and sinoatrial conduction time in sick sinus syndrome are important by performing an electrical stimulation to the atrial muscle. In tachyarrhythmia, if the mechanism of arrhythmia is reentry, it can be induced or terminated by electrical stimulation repeatedly. So that the drug efficacy can be defined by testing the re-inducibility after the drug therapy. If the mechanism of arrhythmia is not clear, the EPS is also performed to make the mechanism of the arrhythmia clear. In triggered activity, especially early after depolarization, the recording of monophasic action potential is useful for diagnosis. EPS can provide the ablation site clear, moreover, the indication of implantable cardioverter defibrillator has been decided by EPS. Therefore, the role of EPS has also been important in selection of non-pharmacological treatment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Enjoji, K Sugi, T Yamaguchi. 1996. [Electrophysiological study].. https://pubmed.ncbi.nlm.nih.gov/8810783/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Role of the dispersion of refractoriness on cardiac reentries.

We used computer simulation to study the possible role of the dispersion of cellular coupling, refractoriness or both, in the mechanisms underlying cardiac arrhythmias. Local ischemia was first assumed to induce cell to cell dispersion of the coupling resistance (case 1), refractory period (case 2), or both (case 3). Our numerical experiments based on the van Capelle and Durrer model showed that vortices could not be induced. On the other hand, with cellular properties dispersed in a patchy way within the ischemic zone, a single activation wave could give rise to abnormal activities. This demonstrates the stability of the wave front under small inhomogeneities. Probabilities of reentry, estimated for the three cases cited above showed that a severe alteration of the coupling resistance may be an important factor in the genesis of reentry. Moreover, use of isochronal maps revealed that vortices were both stable and sustained with an alteration of the coupling alone or along with a reduction of the action potential duration. Conversely, simulations with reduction of the refractoriness alone, inducing only transient patterns, could exhibit functionally determined reentries.

Arrhythmias, Cardiac

Evolving indications for permanent pacing.

Indications for permanent pacemakers have expanded in recent years. The American College of Cardiology (ACC) and American Heart Association (AHA) guidelines for implantation of cardiac pacemakers were recently updated and now include several of the newer indications. Greatest interest about newer applications of pacemaker therapy focuses on hypertrophic obstructive cardiomyopathy, dilated cardiomyopathy, and pacing for the prevention of atrial fibrillation. Pacing for neurocardiogenic syncope remains controversial despite emerging data. Pacing for long QT syndrome, pacing after cardiac transplantation, and pacing for hemodynamic improvement in the occasional patient with first-degree atrioventricular block and hemodynamic compromise also warrant attention. Available clinical data are discussed in the context of the recent ACC and AHA guidelines.

Arrhythmias, Cardiac

Taking advantage of sophisticated pacemaker diagnostics.

The ever-increasing complexity of pacing systems, combined with functions that vary from one manufacturer to another, can pose challenges during analysis of device function. Standard pacemaker diagnostics are measured data, electrogram telemetry, maker annotations and event counters, albeit with their current limitations. New diagnostic features discussed include time-based diagnostics, histograms of sensed amplitudes, pacing thresholds, or impedance trending. Mode-switching algorithms, combined with diagnostic features, facilitate the use of dual-chamber devices in patients with paroxysmal atrial tachyarrhythmias. The introduction of electrogram storage into pacemakers further improves diagnostic capabilities and allows a permanent validation and optimization of diagnostic and therapeutic algorithms. External diagnostic devices, which provide Holter recordings with continuous marker annotations and patient-triggered diagnostics, are additional features that will become increasingly important.

Arrhythmias, Cardiac