Automatic embolus detection compared with human experts. A Doppler ultrasound study.

Abstract

BACKGROUND AND PURPOSE: Transcranial Doppler ultrasound (TCD) reliably detects the occurrence of microembolic signals (MES). Unfortunately, TCD monitoring is a time-consuming and mentally strenuous procedure. The purpose of this study was to assess whether automatic embolus detection software devices acting as a "stand-alone system" are able to identify MES in patients with solid cerebral microemboli. METHODS: Ten records of TCD monitoring of the middle cerebral artery in patients with symptomatic high-grade carotid artery stenosis were analyzed for the moments at which MES occurred by four observers and three automatic detection software devices (RB11 on TC2000, Pioneer Version 2.10, and Embotec). The results of the three software systems were assessed on the basic assumption that MES were present if at least three of the four observers agreed. RESULTS: The average number of 1-second periods in which MES were detected by the four observers per tape ranged from 5 to 39. The overall kappa values (and SEs) for chance-corrected interobserver agreement between the four observers ranged from .94 (.02) to .99 (.01). The agreement between the software devices and the observers was lower, with kappa values (and SEs) ranging from .18 (.17) to .93 (.07). The RB11 and Embotec systems achieved a kappa value higher than 0.4 in all tapes. The Pioneer system failed to reach a kappa value of 0.4 in three tapes. The RB11 showed a sensitivity of 70% for detecting MES, the Embotec 62%, and the Pioneer 44%. CONCLUSIONS: In patients with symptomatic high-grade carotid artery stenosis, a high degree of agreement in the detection of moments of MES can be achieved between observers. The three automatic detection software devices reached less agreement. Supervision of TCD monitoring and assessment of MES by an experienced observer is still necessary.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E V Van Zuilen, W H Mess, C Jansen, I Van der Tweel, J Van Gijn, G A Ackerstaff. 1996. Automatic embolus detection compared with human experts. A Doppler ultrasound study.. https://doi.org/10.1161/01.str.27.10.1840

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Low prevalence of significant carotid artery disease in Iranian patients undergoing elective coronary artery bypass.

BACKGROUND: Coronary artery bypass grafting ranks as one of the most frequent operations worldwide. The presence of carotid artery stenosis may increase the stroke rate in the perioperative period. Routine preoperative noninvasive assessment of the carotid arteries are recommended in many institutions to reduce the stroke rate. METHODS: 271 consecutive patients undergoing coronary artery bypass grafting at Shaheed Madani hospital of Tabriz, Iran (age, 58.5 Y; 73.1% male) underwent preoperative ultrasonography for assessment of carotid artery wall thickness. RESULTS: Plaque in right common, left common, right internal and left internal carotid arteries was detected in 4.8%, 7.4%, 43.2% and 42.1% of patients respectively. 5 patients (1.8%) had significant (<50%) and 3 (1.1%) patients had critical (<70%) stenosis in internal carotid arteries. Plaque formation in common carotid was not significantly different between two genders but the stenosis of left internal carotid was more frequently seen among men. Patients with plaques in right or left internal carotid arteries were significantly older. CONCLUSION: Consecutive Iranian patients undergoing elective coronary artery bypass surgery show a very low prevalence of significant carotid artery disease.

Carotid Stenosis↗