PubMed Health⌕ Search

PubMed · 8847972

Accurate velocity mapping with FAcE.

Abstract

Spin dislocation between the slice selection, phase encoding, and frequency encoding is a source of image distortions. Two strategies can be pursued to improve the appearance of moving spins in an image. Either the sequence is made equally sensitive to velocity-dependent dislocation artifacts for all spatial directions or the sensitivity is reduced with a shorter echo time. The first approach increases the dislocation for the phase-encoding direction and is therefore not useful if velocity maps with minimal distortion are the goal. FAcE (FID acquired echoes) is a sequence with separate sampling of the left and right k-space half-planes that allows for very short echo times. It was applied for velocity mapping of flow in the slice select direction. Special attention was paid to a compact design of the velocity-encoding select gradient to achieve short echo times even with high velocity sensitivity. Artifacts introduced by in-plane motion were studied for FAcE and conventional gradient-echo sequences, both in phantom experiments and simulation. FAcE allows for very short echo times with inherent motion compensation of the frequency-encoding gradient. Thus, both motion-related dislocation artifacts and signal voids due to coherence loss in regions with irregular flow are minimal.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S E Maier, M B Scheidegger, K Liu, P Boesiger. 1996. Accurate velocity mapping with FAcE.. https://doi.org/10.1016/0730-725x(95)02057-z

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗