A glucose biosensor based on an oxygen electrode: in-vitro performances in model buffer solution and in blood plasma.

Abstract

An implantable biosensor for continuous monitoring of glucose levels in diabetic patients was developed. The biosensor is based on an amperometric oxygen electrode and glucose oxidase immobilized on carbon powder held in the form of a liquid suspension. The enzyme material can be replaced (the sensor recharged) without sensor disassembly. Sensors with polycarbonate glucose-diffusion membranes coated with silastic were studied. Calibration curves of the sensors in phosphate buffer solution and in undiluted blood plasma at body temperature were obtained and compared. Sensors were tested for long-term performance in vitro in model phosphate buffer solution and in blood plasma at room and at body temperature. Reproducibility of the sensor responses in plasma at body temperature was demonstrated. During continuous operation at body temperature, the sensors have a lifetime of at least six weeks.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Yang, P Atanasov, E Wilkins. A glucose biosensor based on an oxygen electrode: in-vitro performances in model buffer solution and in blood plasma.. https://pubmed.ncbi.nlm.nih.gov/8850596/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗