PubMed Health⌕ Search

PubMed · 8870059

3D object localization using EIT measurements at two levels.

Abstract

Electrical impedance tomography (EIT) is designed essentially for two-dimensional imaging, but current flow in the third dimension causes images to be formed for objects in 3D. The present work has shown that the image of an object is shifted in position towards the centre almost linearly with the 3D distance from the electrode plane and that the slope of this linear variation depends on the radial distance of the object. An empirical curve has been fitted to this dependence, based on which a method has been developed to locate 3D point objects from EIT measurements in only two planes. This will be useful in clinical and other applications in which 3D objects are few and widely separated. This new methodology may be the basis for 3D imaging in the future.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K S Rabbani, M Hassan, A Kiber. 1996. 3D object localization using EIT measurements at two levels.. https://doi.org/10.1088/0967-3334%2F17%2F3%2F005

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Use of multichannel intraluminal impedance to document proximal esophageal and pharyngeal nonacidic reflux episodes.

Recent studies in adults and children suggest that combined multichannel intraluminal impedance and pH measurement (MII-pH) has the potential to become the new "gold standard" for gastroesophageal reflux testing. In combined MII-pH, reflux is detected by changes in resistance to alternating current induced by the presence of intraluminal materials with different conductivities, and is characterized as acid or nonacid reflux based on concomitant pH measurements. Proximal distribution and duration of nonacid reflux events, predominantly in postprandial periods and during acid-suppressive therapy, can now be quantified. The ability to associate symptoms with nonacid reflux events will help guide therapy in select groups of patients, such as patients with ongoing symptoms on acid-suppressive therapy as well as in the pediatric population.

Electric Impedance↗

Simultaneous determination of the size and surface charge of individual nanoparticles using a carbon nanotube-based Coulter counter.

A resistive-pulse Coulter counter based on a membrane containing a single multiwall carbon nanotube (MWNT) channel was used to simultaneously determine the size and surface charge of carboxy-terminated polystyrene nanoparticles. The membrane was prepared from an epoxy section containing a MWNT channel mounted on a poly(dimethylsiloxane) (PDMS) support structure. The PDMS support reduced the background noise level by a factor of > 20 compared to the Si/Si3N4 support structure used in our previous study. The lower noise level makes it possible to accurately measure the height and width of resistive-pulse signals resulting from transport of individual particles through the MWNT channel. Particle sizes, calculated from current pulse heights, were comparable to those determined by transmission electron microscope (TEM). The width of the current pulses is a measure of the nanoparticle transport time, and it permits calculation of the electrokinetic surface charge. Different types of polystyrene nanoparticles having nearly the same size, but different electrokinetic surface charge, could be resolved on the basis of the difference in their transport time.

Electric Impedance↗

The effect of ohmic heating on vacuum drying rate of sweet potato tissue.

Ohmically heating fruit and vegetable tissue has been shown to increase hot-air drying rate, shift desorption isotherms, and increase juice extraction yields with respect to untreated, conventionally heated, and microwaved samples. The objective of this study was to determine if ohmically heating sweet potato tissue would enhance the vacuum drying rate of these samples with respect to untreated samples. Sweet potato cubes were ohmically heated to three endpoint temperatures using three electrical field strengths and were then placed in a freeze dryer. Moisture content vs. time data were collected and modeled. Results showed that the vacuum drying rates of ohmically heated samples were faster than raw samples for most treatment combinations, and that the maximum reduction of drying time was 24%. Minimal ohmic treatment can result in a significant decrease in vacuum drying time, which could have important economic and product quality implications.

Electric Impedance↗