Remote instrument telemaintenance.

Abstract

In the past decade, great technological progress has been made in telemaintenance of mainframe and mini computers. As hardware technology is now available at an acceptable cost, computer aided trouble-shooting can be adapted to laboratory instrumentation in order to significantly improve repair time, avoid instrument downtime by taking advantage of predictive methods, and provide general diagnostic assistance. Depending on the size of the instrument, the telemaintenance facility can be dedicated to a single instrument or alternatively a telemaintenance server can manage multiple distributed small instruments through a Local Area Network. As complex failures can occur, the local diagnosis capabilities may be exceeded and automatic dialing for connection to computerized Remote Maintenance Centers is needed. The main advantages of such a centre, as compared to local diagnosis systems, are the increased access to more information and experience of failures from instrument installations, and consequently the provision of training data updates for Artificial Neural Networks and Knowledge Based Systems in general. When an abnormal situation is detected or anticipated by a diagnosis module, an automatic alert is given to the user, local diagnosis is activated, and for simple solutions, instructions are given to the operator. In the last resort, a human expert can be alerted who, with remote control tools, can attend to the failures. For both local and remote trouble-shooting, the data provided by the instrument and connected workstation is of paramount importance for the efficiency and accuracy of the diagnosis. Equally, the importance of standardization of telemaintenance communication protocols is addressed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Laugier, N Allahwerdi, J Baudin, P Gaffney, W Grimson, T Groth, L Schilders. 1996. Remote instrument telemaintenance.. https://doi.org/10.1016/0169-2607(96)01746-r

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Enhancement of claims data to improve risk adjustment of hospital mortality.

CONTEXT: Comparisons of risk-adjusted hospital performance often are important components of public reports, pay-for-performance programs, and quality improvement initiatives. Risk-adjustment equations used in these analyses must contain sufficient clinical detail to ensure accurate measurements of hospital quality. OBJECTIVE: To assess the effect on risk-adjusted hospital mortality rates of adding present on admission codes and numerical laboratory data to administrative claims data. DESIGN, SETTING, AND PATIENTS: Comparison of risk-adjustment equations for inpatient mortality from July 2000 through June 2003 derived by sequentially adding increasingly difficult-to-obtain clinical data to an administrative database of 188 Pennsylvania hospitals. Patients were hospitalized for acute myocardial infarction, congestive heart failure, cerebrovascular accident, gastrointestinal tract hemorrhage, or pneumonia or underwent an abdominal aortic aneurysm repair, coronary artery bypass graft surgery, or craniotomy. MAIN OUTCOME MEASURES: C statistics as a measure of the discriminatory power of alternative risk-adjustment models (administrative, present on admission, laboratory, and clinical for each of the 5 conditions and 3 procedures). RESULTS: The mean (SD) c statistic for the administrative model was 0.79 (0.02). Adding present on admission codes and numerical laboratory data collected at the time of admission resulted in substantially improved risk-adjustment equations (mean [SD] c statistic of 0.84 [0.01] and 0.86 [0.01], respectively). Modest additional improvements were obtained by adding more complex and expensive to collect clinical data such as vital signs, blood culture results, key clinical findings, and composite scores abstracted from patients' medical records (mean [SD] c statistic of 0.88 [0.01]). CONCLUSIONS: This study supports the value of adding present on admission codes and numerical laboratory values to administrative databases. Secondary abstraction of difficult-to-obtain key clinical findings adds little to the predictive power of risk-adjustment equations.

Clinical Laboratory Information Systems↗

Definition of an XML markup language for clinical laboratory procedures and comparison with generic XML markup.

BACKGROUND: Clinical laboratory procedure manuals are typically maintained as word processor files and are inefficient to store and search, require substantial effort for review and updating, and integrate poorly with other laboratory information. Electronic document management systems could improve procedure management and utility. As a first step toward building such systems, we have developed a prototype electronic format for laboratory procedures using Extensible Markup Language (XML). METHODS: Representative laboratory procedures were analyzed to identify document structure and data elements. This information was used to create a markup vocabulary, CLP-ML, expressed as an XML Document Type Definition (DTD). To determine whether this markup provided advantages over generic markup, we compared procedures structured with CLP-ML or with the vocabulary of the Health Level Seven, Inc. (HL7) Clinical Document Architecture (CDA) narrative block. RESULTS: CLP-ML includes 124 XML tags and supports a variety of procedure types across different laboratory sections. When compared with a general-purpose markup vocabulary (CDA narrative block), CLP-ML documents were easier to edit and read, less complex structurally, and simpler to traverse for searching and retrieval. CONCLUSION: In combination with appropriate software, CLP-ML is designed to support electronic authoring, reviewing, distributing, and searching of clinical laboratory procedures from a central repository, decreasing procedure maintenance effort and increasing the utility of procedure information. A standard electronic procedure format could also allow laboratories and vendors to share procedures and procedure layouts, minimizing duplicative word processor editing. Our results suggest that laboratory-specific markup such as CLP-ML will provide greater benefit for such systems than generic markup.

Clinical Laboratory Information Systems↗