PubMed Health⌕ Search

PubMed · 8875398

Left ventricular radial tagging acquisition using gradient-recalled-echo techniques: sequence optimization.

Abstract

Myocardial tagging with magnetic resonance (MR) imaging offers unique possibilities for noninvasive left ventricular (LV) strain analysis. True three-dimensional strain analysis can be achieved with tags implemented in cardiac short axis and long axis images. Spin-echo (SE) techniques have been used for these studies. However, this approach is time-consuming: images at different phases of the cardiac cycle have to be obtained in successive measurements and hence the total number of measurements equals the number of time frames. Moreover, the images are often degraded by flow and motion artifacts. The purpose of this study was to optimize a faster and more robust MR tagging sequence for use on a clinical whole-body 1 T MR system with optimal persistence of the tags during the entire cardiac cycle. The tagging pulses were implemented in gradient-recalled-echo (GRE) sequences and compared to SE-based acquisitions. The effects of the use of flow-compensating gradients, the excitation angles, and the angles of the saturation pulses have been studied with MR signal simulations and in comparative measurements in volunteers. GRE acquisitions with flow-compensating gradients are robust techniques for myocardial tagging acquisitions. Use of optimized flip angles and saturation pulses can significantly improve delineation of the tag and can be used up to at least 700 ms after the R-wave. Therefore, LV tagging with GRE acquisitions using optimized MR parameters is a robust and promising technique.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Bosmans, J Bogaert, F Rademakers, G Marchal, G Laub, J Verschakelen, A L Baert. 1996. Left ventricular radial tagging acquisition using gradient-recalled-echo techniques: sequence optimization.. https://doi.org/10.1007/bf01772519

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Tailored SMASH image reconstructions for robust in vivo parallel MR imaging.

The simultaneous acquisition of spatial harmonics (SMASH) imaging technique uses spatial information from an array of RF coils to substitute for omitted encoding gradient steps and thereby to accelerate MR image acquisition. Since SMASH image reconstructions rely on the accurate generation of sinusoidally varying composite sensitivity functions to emulate the spatial modulations produced by gradients, the technique was originally believed to be limited to certain image planes or coil array configurations which were particularly suited to the generation of spatial harmonics. Several key improvements to the SMASH reconstruction procedure are described, taking advantage of various degrees of freedom in the spatial harmonic fit. The use of tailored fitting procedures, in combination with a numerical conditioning approach based on new observations about noise propagation in the fit, are shown to allow high-quality SMASH image reconstructions in oblique and double-oblique image planes, both in phantoms and in high-resolution cardiac MR images. Magn Reson Med 44:243-251, 2000.

Heart↗

Late blood pool images after Tc-99m tetrofosmin injection in a patient with monoclonal gammopathy of uncertain significance and immunologic disorders.

The authors report a case of abnormal biodistribution of Tc-99m tetrofosmin in a patient with immunologic disorders who underwent rest-stress myocardial perfusion scintigraphy to assess the operative risk for surgery of possible relapse of adenocarcinoma of the left maxillary sinus. The patient had monoclonal gammopathy of uncertain significance with a serum electrophoretic pattern of both monoclonal immunoglobulin A and free kappa light chain components and a mild form of idiopathic immunohemolytic anemia. Two different images at rest after injection of Tc-99m tetrofosmin showed a typical blood-pool pattern with absence of detectable myocardial uptake. Other patients injected with the same batch of radiopharmaceutical showed myocardial uptake. A change of the molecular characteristics of tetrofosmin after the injection could not be a factor, because the values of the main chemical and physical parameters of the blood were in the normal range. Accordingly, the authors propose the hypothesis that the monoclonal immunoglobulin A or the free kappa light chains of this patient accidentally recognized one or more epitopes of the tetrofosmin molecule, binding it with high affinity and causing an abnormal biodistribution, characterized by late blood-pool imaging. No similar experiences have been described in the scientific literature.

Heart↗