PubMed Health⌕ Search

PubMed · 8889558

Sensitivity, reproducibility, and accuracy in short tandem repeat genotyping using capillary array electrophoresis.

Abstract

The Human Genome Initiative has increased significantly the rate at which disease-causing genes are being mapped and sequenced. New cost-effective methods to locate the genes and to characterize disease-causing mutations require robust, reproducible, and accurate protocols for measuring DNA fragment lengths. Capillary array electrophoresis (CAE) offers rapid, high-resolution separations, high throughput, and sensitive detection. To assess the utility of CAE for the accumulation of genetic information, we tested both sizing accuracy and reproducibility using 48-capillary prototype systems. Two multiplex PCR allelic ladder standards and several CA-repeat markers were analyzed in > 100 runs. Reproducibility in typing > 8000 genotypes reveals a standard deviation of less than 0.2 bp on these systems under optimized conditions. However, sequence-dependent migration anomalies were observed at most simple sequence loci even when analyzed under denaturing conditions, resulting in a systematic bias in estimated fragment sizes. We show here that, by normalizing results to known typing controls, one can obtain locus-averaged accuracies of < 0.06 bp and normalized results within 1 bp of actual. We detect as little as a 1:30,000 dilution of a DNA quantitation standard stained with highly sensitive intercalating dyes, indicating an 80-zeptomole sensitivity limit. However, to obtain reproducible electrokinetic injection, approximately 200 attomoles of fluorescein-labeled DNA is required. These sensitivity limits, sizing precision, and accuracy, together with the 1-hr run times for 48-96 samples, indicate that CAE is a viable method for high-throughput genetic analysis of simple sequence repeat polymorphisms.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E S Mansfield, M Vainer, S Enad, D L Barker, D Harris, E Rappaport, P Fortina. 1996. Sensitivity, reproducibility, and accuracy in short tandem repeat genotyping using capillary array electrophoresis.. https://doi.org/10.1101/gr.6.9.893

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A study of mixing in thermocapillary flows on micropatterned surfaces.

The recent introduction of actuation mechanisms for microfluidic transport based on free surface flows raises a number of interesting questions involving efficient mixing configurations, especially in systems with small aspect ratios. This work investigates the characteristics of convective and diffusive mixing in continuous-mode streaming of thermocapillary microflows on chemically micropatterned surfaces. Mixing times and mixing lengths relevant to chemical microreactors or gas sensors are investigated for various geometries and parameter ranges. Scaling arguments and full numerical solutions are presented to extract optimal operating conditions. Confocal fluorescence microscopy measurements of the interfacial diffusive broadening in adjacent flowing streams confirm numerical predictions. Three important mixing regimes, based on analogues of purely diffusive dynamics, Rhines-Young shear-augmented diffusion and Taylor-Aris dispersion are identified and investigated for use in free surface flows with large surface-to-volume ratios.

Capillary Action↗

Flow and injection characteristics of pharmaceutical parenteral formulations using a micro-capillary rheometer.

A micro-capillary rheometer consisted of a fine needle with an internal diameter of 347 microm attached to a 1 ml removable-needle syringe within an Instron device that operated in compression mode to provide various crosshead speeds ranging from 150 to 950 mm min(-1) covering typical clinical injection rates, and that determined the resulting force on the plunger. The crosshead speed and the resulting force were used to calculate the shear rate and the shear stress respectively. These were used in standard capillary flow expressions together with an independent measurement of the wall frictional force and allowed the viscosity of parenteral Newtonian solutions and non-Newtonian suspensions to be measured quantitatively and their rheological behaviour in needles of clinical dimensions to be established. Commercial pharmaceutical parenteral formulations consisting of three oil-based solutions and three aqueous suspensions were chosen for this study. The net injection forces were also obtained and it was shown that both the oil-based solutions and the aqueous suspensions covered similar ranges. The viscosities for the parenteral solutions were determined from the slope of the linear regression (R(2)>0.97) between shear stress and shear rate and ranged between 0.029 and 0.060 Pas. For the aqueous suspensions examined, viscosities decreased from low shear rate to high shear rate, following a power-law model and indicating a pseudo plastic behaviour. Standardisation of the micro-capillary rheometer with Newtonian silicone oils calibrated with a Rheometrics Fluids Spectrometer showed viscosity values consistent between the rotational flow measurements and capillary flow measurements which were within 5% and showed very high degrees of reproducibility between replicate samples. This degree of reproducibility allowed differences in the contribution of the wall frictional force to the required plunger force for both the oil-based and aqueous parenteral formulations to be determined reliably. The wall frictional force values for all formulations were similar (0.6-1.6 N) but the frictional forces of aqueous systems were found to decline significantly with plunger speed. The micro-capillary rheometer has been used to evaluate the impact of concentration changes due to sedimentation on the injectability of one of the aqueous suspensions, where it was shown that not only the viscosity increased but the shear thinning behaviour ceased at higher shear rates. The micro-capillary rheometer which was able to operate in clinical shear rate ranges has been shown to detect deteriorations in the injectable rheology of suspensions, which in the case here was due to pre-injection sedimentation.

Capillary Action↗

Trace determination of peptides in water samples using packed capillary liquid chromatography with UV and MS detection and characterization of peptide oxidation products by MS.

A capillary liquid chromatographic column switching method has been developed for fast and sensitive determination of peptides in water samples. Sample volumes of 1 mL were loaded onto a (320 microm I.D. x30 mm) 10 microm Kromasil C(18) pre-column, providing on-line analyte enrichment, prior to back-flushed elution onto a (320 microm I.D. x150 mm) 3.5 microm Kromasil C(18) analytical column. Loading flow rates of 250 microL/min and a mobile phase composition of acetonitrile/water/trifluoroacetic acid (22/77.9/0.1, v/v) provided a total analysis time of less than 25 minutes for the test peptides angiotensin II, bombesin, bradykinin, corazonin, neurotensin and substance P, using temperature programmed elution. In addition, solvent gradient elution and combined solvent gradient elution and temperature programming were explored. Using on-capillary UV detection at 210 nm resulted in a concentration limit of detection (cLOD) of about 1 ng/mL. The method was validated over the concentration range 1-100 ng/mL, yielding a coefficient of correlation of 0.997 or better. The within-assay ( n=6) and between-assay ( n=6) precisions of peak areas were on average 6% RSD and 5% RSD, respectively. When the method was applied to spiked chlorinated tap water samples, it was found that peptides containing methionine, tryptophan and cystine were oxidized. Identification of the oxidation products of the peptides in hypochlorite-treated water was done with positive electrospray ionization time-of-flight mass spectrometric detection.

Capillary Action↗