PubMed HealthSearch

PubMed · 8896326

Organic charge transfer complex based printable biosensor.

Abstract

This paper describes the preparation of an organic charge transfer complex (CTC) based printable enzyme electrode. CTC crystals were prepared by mixing TCNQ powder with TTF solution (in acetonitrile). Glucose oxidase (GOD) was adsorbed at the CTC crystal surface in a monolayer. A printable paste was prepared by mixing GOD-absorbed crystals with a binder and a solvent. This paste was applied to an electrode cavity and vacuum dried. A thin layer of gelatin was cast on the paste filled dried electrode, and cross-linked with glutaraldehyde in the dry condition. The sensors were fixed in a flow injection system, and continuously polarized at 0.15 V and 37 degrees C, and the samples were automatically injected every 30 min. The developed sensors produced a huge response current with an extended linear range of detection (0-100 mM) and the response was unaffected by the presence of normal oxygen in the buffer solution. The sensor showed excellent stability. The performance of the sensors was significantly influenced by the binder used.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G F Khan. 1996. Organic charge transfer complex based printable biosensor.. https://doi.org/10.1016/0956-5663(96)88087-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

From host response to genomic targets: electrochemical biosensing of tuberculosis biomarkers.

Tuberculosis (TB) remains one of the leading causes of death from a single infectious agent worldwide, with timely diagnosis continuing to be a major challenge, particularly in resource-limited settings. Conventional TB diagnostic methods are limited by low sensitivity, long turnaround times, and an inability to reliably differentiate latent from active disease. Biomarker-based diagnostic strategies have therefore gained increasing attention as they offer the potential to improve early detection, disease differentiation, and treatment monitoring. Herein, we examine electrochemical biosensing strategies for TB diagnostics using a biomarker-class-driven framework, covering host-response biomarkers (IFN-γ and TNF-α), pathogen-derived antigens (ESAT6, CFP10, CFP10-ESAT6, MPT64, Ag85, HspX and LpqH), cell-wall signatures and whole-cell markers (LAM and whole cell Mtb), and genomic markers (Mtb DNA and IS6110). Through structured comparison of recognition elements, biointerface designs, signal amplification strategies, electrochemical techniques, matrices, and validation levels, this review identifies the most promising technical approaches for different TB biomarker classes. It further highlights key translational bottlenecks, including limited clinical validation, buffer-based testing, complex multistep amplification, redox-probe dependence, matrix fouling, and insufficient evidence of manufacturability. This review therefore provides practical guidance for developing electrochemical TB biosensors that are analytically sensitive, clinically relevant, and suitable for decentralized diagnostic applications.

Biosensing Techniques

Metal-organic frameworks nanozyme-integrated portable microneedle patch for visual bacterial monitoring in meat.

Foodborne microbial contamination is a major global health concern, with conventional methods often being time-consuming and complex. Herein, we developed a novel portable biosensor by integrating microneedle patch technology and a metal-organic framework (Fe/Cu-NBDC MOF) nanozyme, enabling rapid, on-site, visual detection of bacteria in meat. The sensing system works by encapsulating aptamer-functionalized MOF nanozymes within a hydrogel patch, where their catalytic sites are initially blocked by the aptamer. In the presence of Staphylococcus aureus (S. aureus) as the target, the specific aptamer's binding to bacteria exposes numerous catalytic sites, further activating the chromogenic reaction of the tetramethylbenzidine‑hydrogen peroxide (TMB-H₂O₂) system, enabling visual detection of S. aureus. The biosensor demonstrates a detection limit of 82 CFU/mL with excellent specificity to successfully apply to commercial mutton. By integrating sampling, enrichment, and visual detection into a single compact device, this platform offers a practical, efficient solution for rapid on-site screening of foodborne pathogens.

Biosensing Techniques

Ferrocene-conjugated m-phenylenediamine conducting polymer-incorporated peroxidase biosensors.

The development and characteristics of a reagentless amperometric biosensor employing horseradish peroxidase incorporated in an electrochemically deposited ferrocene-modified phenylenediamine film on a glassy carbon electrode is reported. The horseradish peroxidase/poly(m-aminoanilinomethylferrocene)- modified glassy carbon electrode reagentless biosensor measured hydrogen peroxide and other organic peroxides in both aqueous and organic medium by reduction at a low applied potential of -0.05 V (vs Ag/AgCl) without interference from molecular oxygen. When modified with glucose oxidase, the new bienzyme electrode measured glucose sensitively and selectively, demonstrating the suitability of the above peroxide biosensor for other oxidoreductase enzyme-based biosensors.

Biosensing Techniques