PubMed Health⌕ Search

PubMed · 8912298

Finding the optimal multiple-test strategy using a method analogous to logistic regression: the diagnosis of hepatolenticular degeneration (Wilson's disease).

Abstract

Finding the optimal strategy among a battery of tests may be cumbersome for decision analytic models. The authors present a method of examining multiple test combinations that is based on a modified Bayes' formula analogous to logistic regression. They examined all 16 combinations of four tests used to diagnose hepatolenticular degeneration. The four tests examined were: serum ceruloplasmin level, 24-hour urinary copper excretion, free serum copper level, and liver biopsy copper concentration. They also simulated the diagnostic workup of the disease for a hypothetical cohort of 15,000 patients at risk. Assuming the disutilities of false positives and false negatives to be equal, and considering sensitivity analysis of test characteristics, the following test combinations were found to be optimal for making the diagnosis at a prior probability of disease equal to 0.05: positive serum ceruloplasmin and 24-hour urinary copper excretion, combined with either positive liver biopsy or free serum copper (or both). The strategies obtained by the modified Bayes' formula were the same as those found using the simulated data set with a standard logistic-regression software package. The logistic model's diagnostic accuracy is 0.98 as measured by the area under the receiver operating characteristic curve. The optimal strategy for diagnosing hepatolenticular degeneration varies with the prior probability of disease. For prior probabilities of 0.05, 0.25, and 0.9, and the optimal strategy, model sensitivities are 0.801, 0.880, and 0.997, and model specificities are 0.991, 0.985, and 0.814, respectively. The new method provides a convenient alternative to decision trees when examining multiple diagnostic tests.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R J Richards, J K Hammitt, J Tsevat. Finding the optimal multiple-test strategy using a method analogous to logistic regression: the diagnosis of hepatolenticular degeneration (Wilson's disease).. https://doi.org/10.1177/0272989x9601600407

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Smooth semiparametric receiver operating characteristic curves for continuous diagnostic tests.

We propose a semiparametric kernel distribution function estimator, based on which a new smooth semiparametric estimator of the receiver operating characteristic (ROC) curve is constructed. We derive the asymptotic bias and variance of the newly proposed distribution function estimator and show that it is more efficient than the traditional non-parametric kernel distribution estimator. We also derive the asymptotic bias and variance of our new ROC curve estimator and show that it is more efficient than the smooth non-parametric ROC curve estimator proposed by Zou et al. (Stat. Med. 1997; 16:2143-2156) and Lloyd (J. Am. Stat. Assoc. 1998; 93:1356-1364). For our proposed estimators, we derive data-based methods for bandwidth selection. In addition, we present some results on the analysis of two real data sets. Finally, a simulation study is presented to show that our estimators are better than the non-parametric counterparts in terms of bias, standard error, and mean-square error.

Area Under Curve↗

Redox potential measurement as a rapid method for microbiological testing and its validation for coliform determination.

The redox potential is one of the most complex indicators of the physiological state of microbial cultures and its measurement could be a useful tool for the qualitative and quantitative determination of the microbial contamination. During the bacterial growth, the redox potential of the medium decreases. The shape of the redox potential curve is characteristic on the type of microorganism, and the rate of the change (dE/dt) is proportional to the living cell concentration. Defining the time required to reach a significant change in redox potential as Time to Detection (TTD), similarly to the impedimetric measurements, a strict linear correlation could be established between the TTD and the logarithm of the initial concentration of microorganisms. On the base of this calibration curve, the determination of living cell concentration could be simplified. For the experiments, a computer-controlled multi-channel measuring system and software was developed by the authors. The redox potential measurement method was tested and validated for the determination of coliform bacteria. The results have proved the high efficiency and reliability of the new method.

Area Under Curve↗

Determination of N-methyl-4-isoleucine-cyclosporin (NIM811) in human whole blood by high performance liquid chromatography-tandem mass spectrometry.

A liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the determination of N-methyl-4-isoleucine-cyclosporin (NIM811) was developed and validated over the concentration range 1-2500 ng/mL in human whole blood using a 0.05 mL sample volume. NIM811 and the internal standard, d(12)-cyclosporin A (d(12)-CsA), were extracted from blood using MTBE via liquid-liquid extraction. After evaporation of the organic solvent and reconstitution, a 10 microL aliquot of the resulting extract was injected onto the LC-MS/MS system. Chromatographic separation of NIM811 and internal standard was performed using a Waters Symmetry RP-8 (50 x 4.6 mm, 3 microm particle size) column. The mobile phase consists of 10 mm ammonium acetate in water (A) and acetonitrile (B), with 45% B from 0 to 0.2 min, 45 to 85% B from 0.2 to 0.8 min and 85% B from 0.8 to 2.2 min. The total run time was 3.5 min with a flow rate of 0.8 mL/min. The method was validated for sensitivity, linearity, reproducibility, stability, dilution integrity and recovery. The precision and accuracy of quality control samples at low (2.00 ng/mL), medium (20.0 and 400 ng/mL) and high (2000 ng/mL) concentrations were in the range 1.1-4.3% relative standard deviation (RSD) and -2.5-10.0% (bias), respectively, from three validation runs. The method has been used to measure the exposure of NIM811 in human subjects.

Area Under Curve↗