PubMed HealthSearch

PubMed · 8917203

Problems with fractionated cold kits.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Decristoforo, G Riccabona. 1996. Problems with fractionated cold kits.. https://pubmed.ncbi.nlm.nih.gov/8917203/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The prediction of the structure of technician (V) complexes using density-functional techniques.

Electronic structure calculations using the local-density functional method were shown to accurately reproduce the geometry of five oxo-Tc (V)-based radiopharmaceuticals containing a variety of donor ligands. Calculations were performed using the DGauss program on a Cray C90 supercomputer, requiring approximately 40 CPU h for each molecule. The predicted bond lengths were within +/- 0.04 A of the crystallographic coordinates, and bond angles within +/- 4 degrees. Root mean square (RMS) deviations between the predicted and crystallographic coordinates were less than 0.06, and visual inspection demonstrated nearly perfectly superimpossible structures.

Organotechnetium Compounds

A comparison of three methods to determine the radiochemical purity of 99Tcm-hexamethylpropylene amine oxime (99Tcm-HMPAO).

Determining the radiochemical purity of 99Tcm-HMPAO using the standard method suggested by the manufacturer of the HMPAO kit is slow, consuming much of the 30 min useful shelf-life of the radiopharmaceutical. We have compared two new methods (a solvent extraction technique and a method involving a disposable, pre-packed reverse phase chromatography cartridge) with the standard method for determining the radiochemical purity of 99Tcm-HMPAO. There were no significant differences (F test, p less than 0.05) in the results obtained by all three methods. However, the reversed phase chromatography method gave better agreement (correlation coefficient of 0.877) with results obtained using the standard method than did the solvent extraction technique (correlation coefficient of 0.693). The solvent extraction technique took about 10 min to perform whereas the reversed phase chromatography method took only 5 min. Both of the new methods did not achieve complete separation of the secondary, less lipophilic 99Tcm-HMPAO complex from the primary, lipophilic 99Tcm-HMPAO complex but the error introduced was small (typically only 3-5%). The new methods offer the capability of determining the radiochemical purity of 99Tcm-HMPAO quickly, reliably and accurately, prior to administration of the radiopharmaceutical to the patient.

Organotechnetium Compounds