Extracorporeal shock wave lithotripsy.

Abstract

The first clinical application of extracorporeal SWL dates back to 1980. Since then the use of this method has spread widely and its indications have been extended progressively so that it way now be considered the treatment of choice in 80-90% of cases of ureterorenal lithiasis. Treatments without anesthesia or analgesics have been associated with an increase of retreatments from 5-14% (original HM3) to 45-60% (lithotripters not requiring anesthesia or analgesia). However, almost all lithotripter succeed in fragmenting stones sufficiently. The stone free rate varies with different lithotripters in the different series: 90-56% for stones of maximum diameter < 1 cm, 78-30% for stones of maximum diameter of 1-2 cm. and 52.5-10% for stones of maximum diameter of 2-3 cm. (the last figure was obtained with a piezoelectric lithotripter). Extracorporeal lithotripsy as monotherapy of staghorn stones has yelded a stone free rate varying between 31% and 55% with high percentages of residual fragments in about 50% of case of the various series. The stone free rate after treatment varies according to stone site: it is between 75% and 84% of caliceal stones for upper caliceal calculi and falls to under 60% for lower caliceal ones. The frequency of recurrences, that is, of new stones in patients stone free after SWL, is between 4% and 10% annually. Adding the percentage of true recurrences reported by the various authors at 19 to 42 months of follow-up (6.2-13.8%) to the fragment regrowth rate (17.2-22.3%) gives a total new stone rate of 23.4% and 36%. These figures are not greatly different from those reported in a population of untreated stone formers (10-15% per year). Extracorporeal lithotripsy seems thus not to influence lithiasis recurrence significantly.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Zanetti, M Seveso. 1996. Extracorporeal shock wave lithotripsy.. https://pubmed.ncbi.nlm.nih.gov/8936718/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dual-trap technique for reduction of low-frequency noise in force measuring optical tweezers.

High-resolution long-time force measurements by optical tweezers are often limited by low-frequency (1/f) noise. A dual-trap technique is presented that can reduce such noise in the force signal. It incorporates a second trap (a reference trap) that probes the noise in the system and it is based upon the assumption that the low-frequency parts of the noise from the two traps are correlated. A subtraction of the low-frequency signal from the reference trap from the signal from the force measuring trap will therefore yield a net signal that is significantly less influenced by noise. It is shown that this dual-trap technique can reduce the noise in the force signal up to 60% depending on detection bandwidth.

Equipment Design↗

Optimization of doses received by the hospital staff and the members of the family of patients undergoing 111In-DTPA-D-Phe1-Octreotide therapy.

According to the Euratom Directives (96/29, 97/43), the doses received by the workers as well as the family of patients and third persons during medical exposures, should conform to the dose constraint levels (DCLs), established by the authorities for each group in the context of optimisation. This study deals with the implementation of a radiation protection protocol, concerning the aforementioned group members for patients undergoing treatment with 111In-DTPA-D-Phe1-Octreotide, after intra-arterial infusion. It is shown that by applying this protocol the annual doses to the medical and technical staff are considerably reduced and remain below the established DCLs. Following the post-release behaviour instructions given to the patient, doses to the family and third persons may be kept lower than the corresponding DCLs provided by the National Regulations.

Equipment Design↗

In vivo myograph measurement of muscle contraction at optimal length.

BACKGROUND: Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. METHODS: We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. RESULTS: In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. CONCLUSION: We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.

Equipment Design↗