PubMed Health⌕ Search

PubMed · 8946792

Solid phase microextraction for quantitative headspace sampling of apple volatiles.

Abstract

Solid phase microextraction (SPME) was evaluated for use in the quantification of aroma volatile production by Granny Smith apples during cool storage. Particular attention was paid to quantifying alpha-farnesene (3,7,11-trimethyldodeca-1,3(E),6(E),10-tetraene) due to its involvement in superficial scald, a disorder of cool stored apples. Comparison between SPME and solid phase extraction (SPE) showed that the SPME fiber had greater adsorption of high molecular weight (MW) volatiles such as alpha-farnesene. When sampling by SPME, these higher MW volatiles did not equilibrate between apples, headspace, and fiber within sampling times as long as 90 min, while lower MW volatiles equilibrated within 5 min. This behavior was also shown by a simple model system consisting of five selected volatiles dissolved in an involatile, lipophilic liquid (squalane). The less volatile high MW aroma compounds evaporated slowly from the surface of the apples and were depleted from the headspace because of very rapid adsorption by the SPME fiber. The amount of alpha-farnesene adsorbed by the fiber increased with air movement through the system. In a static headspace system, the amount of alpha-farnesene adsorbed by the fiber decreased nonlinearly with increasing distance from the apples, due to adsorption onto the glass walls. While SPME is ideal for rapid, qualitative determination of apple headspace volatiles, the slower equilibration of higher MW volatiles limits its use for quantification in more complex systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A J Matich, D D Rowan, N H Banks. 1996-12-01. Solid phase microextraction for quantitative headspace sampling of apple volatiles.. https://doi.org/10.1021/ac9604548

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Sol-gel immobilization of serine proteases for application in organic solvents.

The serine proteases alpha-chymotrypsin, trypsin, and subtilisin Carlsberg were immobilized in a sol-gel matrix and the effects on the enzyme activity in organic media are evaluated. The percentage of immobilized enzyme is 90% in the case of alpha-chymotrypsin and the resulting specific enzyme activity in the transesterification of N-acetyl-L-phenylalanine ethyl ester with 1-propanol in cyclohexane is 43 times higher than that of a nonimmobilized lyophilized alpha-chymotrypsin. The activities of trypsin and subtilisin Carlsberg are enhanced with 437 and 31 times, respectively. The effect of immobilization on the enzyme activity is highest in hydrophobic solvents.

Chromatography, Gas↗

Liquid crystalline polysiloxane polymer as stationary phase in gas chromatography capillary column for the separation of dioxin/furan compounds.

A side-chain liquid crystalline polysiloxane polymer (PS3DBDE1) with high purity and high isotropic transition temperature served as a stationary phase in an attempt to chromatographize the dioxin/furan compounds. The polymer was coated on the inner surface of a 0.25 mm I.D. capillary column by using the static coating method, forming a film with a thickness of df approximately 0.25 microm. A commercial standard solution (US EPA 1613 standard solution 1613CS4) containing polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) was used to test the chromatographic behavior of the laboratory-made capillary column. Two commercial capillary columns HP-5MS (Hewlett-Packard) and RTX-5MS (RTX) were chosen to compare their chromatographic behavior. The results show that by the use of PS3DBDE1 the isomeric pair compounds 1,2,3,4-TeCDD vs. 2,3,7,8-TeCDD and 1,2,3,4,7,8-HxCDD vs. 1,2,3,6,7,8-HxCDD and the same substituted-chlorine number compounds 1,2,3,4,6,7,8-HpCDF vs. 1,2.3,4,6,7,8-HpCDD and 1,2,3,4,6,7,8,9-OCDD vs. 1,2,3,4,6,7,8,9-OCDF had higher resolution than HP-5MS and RTX-5MS as suggested by the column makers.

Chromatography, Gas↗

Selectivity assessment of DB-200 and DB-VRX open-tubular capillary columns.

The solvation parameter model is used to study the influence of composition and temperature on the selectivity of two poly(siloxane) stationary phases used for open-tubular capillary column gas chromatography. The poly(methyltrifluoropropyldimethylsiloxane) stationary phase, DB-200, has low cohesion, intermediate dipolarity/polarizability, low hydrogen-bond basicity, no hydrogen-bond acidity, and repulsive electron lone pair interactions. The DB-VRX stationary phase has low cohesion, low dipolarity/polarizability, low hydrogen-bond basicity and no hydrogen-bond acidity and no capacity for electron lone pair interactions. The selectivity of the two stationary phases is complementary to those in a database of 11 stationary phase chemistries determined under the same experimental conditions.

Chromatography, Gas↗