[A new solid-phase extraction method for human urinary 3-methoxy-4-hydroxyphenylethyleneglycol].

Abstract

A new solid-phase extraction procedure for urinary 3-methoxy-4-hydroxy-phenylethyleneglycol (MHPG) was established. Sep-Pak Diol cartridge was used, because MHPG is a neutral and alcoholic compound. Aqueous samples were adsorbed to the cartridge, then MHPG was eluted by the addition of ethyl acetate. After the eluate was evaporated, the residuum was dissolved with HPLC mobile phase and injected into HPLC. The extraction procedure was highly specific to MHPG, and none of other acidic catecholamine metabolites, such as vanillylmandelic acid (VMA), homovanillic acid (HVA) and 3,4-dihydroxyphenylacetic acid (DOPAC), was extracted. The recovery of MHPG using this method was over 90% and higher than those using previously described methods such as liquid-liquid extraction with ethyl acetate. Of the three vanillyl alcohol isomers, isovanillyl alcohol was the most suitable as an internal standard for the correction of column-to-column variation of the recovery. Human urinary unconjugated MHPG extracted by the new procedure could be measured by HPLC with a fluorescence detection. Further complicated derivatization and more sensitive detection systems, such as GC-MS and HPLC-electrochemical detector (ECD), were not needed due to high selectivity and high recovery of the extraction procedure. In addition, the urinary total (conjugated plus unconjugated) MHPG content could also be determined by the same procedure after an enzymatic hydrolysis of conjugated MHPG. The newly developed extraction procedure was simple, rapid and highly specific, and might be applicable to the analysis of MHPG in various body fluids.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Hirata, H Inagaki, M Minami. 1996. [A new solid-phase extraction method for human urinary 3-methoxy-4-hydroxyphenylethyleneglycol].. https://doi.org/10.1248/yakushi1947.116.10_813

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Nickel-catalyzed N-terminal oxidative deamination in peptides containing histidine at position 2 coupled with sulfite oxidation.

Peptides containing histidine at position 2 were observed to undergo spontaneous N-terminal oxidative deamination in aqueous solution in the presence of Ni(II), sulfite, and ambient oxygen. The reaction resulted in the formation of a free carbonyl on the N-terminal alpha-carbon (alpha-ketoamide) and was catalytic with respect to nickel. This oxidative deamination was confirmed by 13C NMR, 1H NMR, mass spectrometry, and chemical tests. No evidence of modification of histidine was found. It was demonstrated that the nickel-dependent N-terminal oxidative deamination also occurred in His-2 peptides using potassium peroxymonosulfate (oxone) as an oxidant. When oxone was used, oxygen was not required for the deamination to proceed. The results suggest that both nickel-catalyzed reactions (sulfite and oxygen, and oxone) produce an imine intermediate that spontaneously hydrolyzes to form the free carbonyl. These findings may provide a physiologically relevant model for oxidative carbonyl formation in vivo, as well as a useful method for producing a site-specific carbonyl on peptides and proteins.

Chromatography, High Pressure Liquid

Elongation of oligopeptides in a simulated submarine hydrothermal system.

Oligomerization of a peptide was attempted in a flow reactor that simulated a submarine hydrothermal system. When fluid containing glycine repeatedly circulated through the hot and cold regions in the reactor, oligopeptides were made from glycine. When divalent ions (such as copper ions) were added under acidic conditions, oligoglycine was elongated up to hexaglycine. This observation suggests that prebiotic monomers could have oligomerized in the vicinity of submarine hydrothermal vents on primitive Earth.

Chromatography, High Pressure Liquid

Ultrahigh-pressure reversed-phase capillary liquid chromatography: isocratic and gradient elution using columns packed with 1.0-micron particles.

Fused-silica capillaries with inner diameters of 33 microns and lengths of 25-50 cm are slurry-packed with 1.0-micron nonporous octadecylsilane-modified (C18) silica spheres. These columns are used to perform ultrahigh-pressure reversed-phase liquid chromatographic analyses in both isocratic and gradient elution modes. Mobile-phase pressures as high as 5000 bar (72,000 psi) are applied to column inlets to generate more than 200,000 theoretical plates in 6 min (k' approximately 1) for small, organic analytes. Average capacity factors of analytes are found to increase linearly with applied pressure. An electrically driven constant-flow syringe pump capable of generating mobile-phase pressures as high as 9000 bar (130,000 psi) is described. This pump is used in conjunction with an exponential dilution method for the gradient separation of peptides from a tryptic digest on a 27-cm-long capillary packed with 1.0-micron particles. A peak capacity of 300 is demonstrated for a 30-min analysis.

Chromatography, High Pressure Liquid