PubMed HealthSearch

PubMed · 8978866

Developing a computer-based expert system for pediatric prosthetic training: a pilot project.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L M Stelzer, C Creighton. 1997. Developing a computer-based expert system for pediatric prosthetic training: a pilot project.. https://doi.org/10.5014/ajot.51.1.70

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Accuracy and precision of volumetric determinations using two commercial CAD systems for prosthetics: a technical note.

The aim of this study was to evaluate the validity and reliability of volume determinations using the commercially available Seattle ShapeMaker CAD/CAM system for production of prosthetic sockets and to compare it with the commercially available CAPOD system. We used three types of reference objects for volumetric determinations: steel tubes, plaster of Paris casts, and residual limb models. Three different sizes were examined for each type of object. Volume measurements with the two CAD/CAM systems were compared with measurements obtained by water filling, water immersion, or mathematical calculation (tubes only). We found an inconsistent systematic error of less than 3.1% for ShapeMaker and no systematic error for CAPOD. Random errors, represented by the coefficient of variation, were below 1.3% for the ShapeMaker and, in most cases, below 0.4% for the CAPOD. Theoretical changes in volume of 2.6% and 0.8% are possible to detect with these CAD/CAM systems. In our opinion, both systems have sufficient precision for routine clinical use in prosthetics and orthotics. However, in our study, the ShapeMaker committed larger random and systematic errors than CAPOD. This means that, according to our study, CAPOD offers the best possibility to determine and detect small changes in residual limb volume as a function of time.

Artificial Limbs

Lower extremity residual limb slippage within the prosthesis.

OBJECTIVE: The ability to measure skin surface slippage relative to the internal wall of a lower extremity prosthesis under various loading conditions is important for evaluation of socket fit and function, and creation of finite element models. Skin surface three-dimensional (3D) shape measurements with tracking of fiducial displacements in situ under axial loading of the prosthesis have not previously been reported. Analysis of slippage within the prosthesis has been performed using a new experimental measurement method based on spiral x-ray computed tomography (SXCT) imaging. DESIGN: Small lead markers were placed on the residuum of an adult with a below-knee amputation, and SXCT scans were obtained with the prosthesis in situ under two static axial loading conditions (44.5N and 178N). The 3D scan data were used to assess slippage with three methods: gross displacement of the tibia and distal end of the residuum; relative displacement of markers; and distance measurements between markers. RESULTS: The markers affixed to the below-knee skin surface within the prosthesis were measured. The skin slipped from 2 to 6 mm relative to the internal prosthesis wall when an additional load of 133.5N was applied in the axial direction to the distal end of the prosthesis. The tibial remnant moved 10.0 mm distally relative to the prosthesis internal wall. CONCLUSION: This method provides a feasible means for measuring residuum skin slippage relative to the prosthesis and skin deformation relative to tibia within an in situ prosthesis under load.

Artificial Limbs