Statistical methods of computing reference values for side-to-side differences in nerve conduction studies.

Abstract

This study uses theoretic derivations, statistical simulations, and empirical estimations to compare two ways of deriving reference values for side-to-side differences in nerve conduction parameters of healthy subjects. The two methods involve using the side-to-side differences (STSD) and the absolute values of the STSD (AVSTSD). The theoretic derivations showed that the population reference value of the AVSTSD is greater than the STSD reference values by 0.18%. Simulation studies showed that the AVSTSD yields greater sampling errors than the STSD method when establishing the reference values for nerve conduction parameters. However, the sampling variability is substantially reduced by using study samples of greater than 50, and the differences between the two methods in sampling errors are trivial as sample size approaches 100. Using H reflex (HR) and extensor digitorum brevis reflex (EDBR) clinical data, the two methods were compared. In contrast to the small theoretic differences in reference values, the AVSTSD method overestimated the reference value by 0.5 ms for the EDBR and 0.1 ms for the H reflex, when using data from a population sample, increasing the type II error (reducing sensitivity) for the EDBR. The STSD method is recommended for establishment of normal values and for clinical comparisons.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A S Chang, T R Dillingham, K F Yu. Statistical methods of computing reference values for side-to-side differences in nerve conduction studies.. https://doi.org/10.1097/00002060-199611000-00007

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A software tool to acquire, synchronise and playback multimedia data: an application in kinesiology.

Assessing the physical condition of the human body frequently requires evaluating different tests performed by different devices. This information has to be analysed simultaneously to derive conclusions, and so a temporal relationship must be established between the data sources. In this paper, synchronisation of the sources of information is achieved by synchronising the clocks of computers connected in a Local Area Network. A clock synchronisation protocol is used and a global time is stamped in each information data flow. During analysis, the time-stamp is used to playback the data in a synchronised way. The proposed system is valid for any medical application in which data synchronisation is needed. However, it has initially been used in a distributed medical environment for analysing electrical muscular activity and lumbar movement. The dual aim is to detect injuries and plan training sessions for athletes. It was specifically used to analyse data generated by: electromyographs; lumbar equipment; and images generated by video cameras. The simple operation of the application and the precision of the synchronisation protocol enabled several interesting medical conclusions to be made.

Electromyography