PubMed HealthSearch

PubMed · 903543

Temporal arteritis.

Abstract

Temporal arteritis (granulomatous inflammation) usually involves the temporal and ophthalmic arteries, but may be part of a more widespread inflammation of the medium and large vessels. The patient usually presents with an associated group of constitutional symptoms (fever, malaise, anorexia, weight loss, anemia) and rheumatic complaints (polymyalgia rheumatic complaints (polymyalgia rheumatica). The diagnosis should be considered in any patient over 55 years old in whom these symptoms develop or in whom there is evidence of recent onset of headache, visual loss of localized arterial involvement. The diagnosis is also to be considered when the erythrocyte sedimentation rate is over 50 mm/hr, and the presence of arteritis is confirmed by temporalartery biopsy findings. Visual loss may occur in 50 percent of affected patients; other serious complications are less common. A strong clinical suspicion of temporal arteritis will permit diagnosis of the more uncommon and atypical presentations of the syndrome. Although cases of temporal arteritis may be self-limited, treatment is imperative because of the threat of blindness. Patients respond well to steroid (prednisone) therapy, which should be maintained for a prolonged period.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T J Murray. 1977. Temporal arteritis.. https://doi.org/10.1111/j.1532-5415.1977.tb00805.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Estimates of mean alveolar PCO2 during steady-state exercise in man: a theoretical study.

The partial pressure of carbon dioxide in arterial blood is an important operator in the control of breathing, by actions on peripheral and central chemoreceptors. In experiments on man we must often assume that lung alveolar PCO2 equals arterial PCO2 and obtain estimates of the former derived from measurements in expired gas sampled at the mouth. This paper explores the potential errors of such estimates, which are magnified during exercise. We used a published model of the cardiopulmonary system to simulate various levels of exercise up to 300 W. We tested three methods of estimating mean alveolar PCO2 (PACO2) against the true value derived from a time average of the within-breath oscillation in steady-state exercise. We used both sinusoidal and square-wave ventilatory flow wave forms. Over the range 33-133 W end-tidal PCO2 (P(et)CO2) overestimated PACO2 progressively with increasing workload, by about 4 mmHg at 133 W with normal respiratory rate for that load. PCO2 by a graphical approximation technique (PgCO2; "graphical method") underestimated PACO2 by 1-2 mmHg. PCO2 from an experimentally obtained empirical equation (PnjCO2; "empirical method") overestimated PACO2 by 0.5-1.0 mmHg. Graphical and empirical methods were insensitive to alterations in cardiac output or respiratory rate. End-tidal PCO2 was markedly affected by respiratory rate during exercise, the overestimate of PACO2 increasing if respiratory rate was slowed. An increase in anatomical dead space with exercise tends to decrease the error in P(et)CO2 and increase the error in the graphical method. Changes in the proportion of each breath taken up by inspiration make no important difference, and changes in functional residual capacity, while important in principle, are too small to have any major effect on the estimates. Changes in overall alveolar ventilation which alter steady-state PACO2 over a range of 30-50 mmHg have no important effect. At heavy work loads (200-300 W), P(et)CO2 grossly overestimates by 6-9 mmHg. The graphical method progressively underestimates, by about 5 mmHg at 300 W. A simulated CO2 response (the relation between ventilation and increasing PCO2) performed at 100 W suggests that a response slope close to the true one can be obtained by using any of the three methods. The graphical method gave results closest to the true absolute values. Either graphical or empirical methods should be satisfactory for detecting experimentally produced changes in PACO2 during steady-state exercise, to make comparisons between different steady-state exercise loads, and to assess CO2 response in exercise.(ABSTRACT TRUNCATED AT 400 WORDS)

Arteries

Comparative effects of endothelin (ET-1) and U46619 on human saphenous vein and gastroepiploic artery, sources of human autologous grafts.

The effects of endothelin (ET-1) on smooth muscle contractile activity were investigated and compared in human saphenous vein and gastroepiploic artery, vessels frequently used in revascularization procedures. ET-1 contracted saphenous vein and gastroepiploic artery in a concentration-dependent manner. The peptide produced a greater maximal effect in the vein than in the artery and, in both preparations, ET-1 was less efficacious than U46619, an agent which mimics the actions of thromboxane A2 at the thromboxane A2/prostaglandin H2 receptor. The contractile response to ET-1 declined spontaneously at a more rapid rate in the artery than in the vein. The present data indicate that ET-1 has significant contractile activity in both vessels which are used for coronary arterial bypass surgery and suggest that although, a weaker vasoconstrictor than U46619, the peptide could induce vasospasm in both graft vessels.

Arteries

Quantitative histochemical analysis of human artery using Raman spectroscopy.

We have developed a method for using near infrared Raman spectroscopy to quantitatively analyze the histochemical composition of human artery. The main contributors to bands observed in the Raman spectra of normal and atherosclerotic aorta are the proteins collagen and elastin, cholesterol lipids, and calcium hydroxyapatite. The Raman scattering cross-sections of different bands for these components have been determined in order to understand their relative contributions to the Raman spectra of biological tissue. The Raman signal is observed to behave linearly with the concentration of the components, even in a highly scattering medium such as a powder. Using these data, we have developed a linear model that can be used to extract the quantitative contribution of an individual component to the spectrum of a mixture. The model has been applied to several mixtures of known composition of tissue constituents in order to evaluate its precision and accuracy. The calculated fit coefficients from the spectra are in agreement with the measured values within experimental uncertainties. The spectra of different types of atherosclerotic aorta have also been modeled, and we have extracted quantitative information regarding the relative concentration of biological constituents in atherosclerotic aorta.

Arteries