Reducing flow artifacts in echo-planar imaging.

Abstract

Echo-planar imaging (EPI) is very susceptible to flow artifacts. Two ways to improve its flow properties are presented. First, "partial flyback" is proposed to reduce artifacts arising from flow in the readout direction. Near the center of k-space, only the even echoes of the EPI echo-train are used. Partial flyback is shown to improve the readout-flow properties at the expense of a slight worsening of the phase-encode flow and off-resonance properties. We recommend that the flyback region acquire 95% of the energy in k-space. Second, "inside-out" EPI is used to reduce artifacts arising from flow in the phase-encode direction. Data collection begins at the center of k-space, with separate interleaves to acquire the top and bottom, halves of k-space. Partial flyback is combined with partial-Fourier EPI and inside-out EPI. Partial-flyback inside-out EPI has worse off-resonance properties than partial-flyback partial-Fourier EPI but demonstrates better flow properties and does not require partial k-space reconstruction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G T Luk Pat, C H Meyer, J M Pauly, D G Nishimura. 1997. Reducing flow artifacts in echo-planar imaging.. https://doi.org/10.1002/mrm.1910370323

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Assessment of myocardial viability by radionuclide imaging.

The differentiation of viable from non viable myocardium is a key issue in the current era of revascularization. Several methods have been used to assess myocardial viability. The radionuclide detection of dysfunctional but viable myocardium depends upon the use of radiotracers whose uptake and trapping are related to presence and amount of living cells. The choice of the diagnostic technique to be applied in clinical practice depends on accuracy of the method and availability of resources. SPECT imaging with TI-201 and Tc-99m-myocardial perfusion tracers are widely available diagnostic tools. Several studies have documented their reliability to detect myocardial segments which may improve in both perfusion and function after revascularization. Positron emission tomography after injection of glucose analogues is a more sophisticated and accurate technology to detect viability, whose utilization is at present limited to few centers due to its high cost. Therefore an accurate selection of patients requiring viability studies is needed in order to identify the most appropriate diagnostic test.

Heart

Improved sampling of myocardial motion with variable separation tagging.

A novel tagging method is introduced that increases the spatial resolution of estimates of myocardial radial thickening. The separation of adjacent parallel tag planes is customized to match the expected motion of specific regions of the heart wall. In regions in which the tags increase their separation over systole (radial thickening), the tag planes are placed close together at end diastole. In regions in which the tags decrease their separation over systole (circumferential shortening), the tags are placed farther apart so they remain detectable at end systole. With variable separation tagging (VTAG), parallel plane tagging can be used to obtain higher-resolution estimates of radial thickening and circumferential shortening simultaneously.

Heart