PubMed Health⌕ Search

PubMed · 9056600

Absolute quantitation of diffusion constants in human stroke.

Abstract

BACKGROUND AND PURPOSE: Animal studies have shown that MR diffusion imaging can outline acute ischemic regions before irreversible damage (infarction) occurs. To study evolution of ischemic lesions in humans, it is therefore important to quantify absolute diffusion constants (D values), but quantitation has not been reproducible among different clinics. These problems are explained, and a method for reproducible quantitation is suggested. METHODS: Diffusion-weighted and absolute diffusion images were acquired, and the absolute apparent diffusion constants in three orthogonal spatial directions (Dxx, Dyy, and Dzz) were measured. These were combined to calculate images of the orientation-independent apparent diffusion parameter Dav = 1/3 Trace[D] = 1/3(Dxx + Dyy + Dzz). Values of the individual diffusion constants and Dav were evaluated in 6 patients and 6 normal volunteers. RESULTS: Patient data show that comparison of diffusion constants between contralateral and ipsilateral hemispheres after ischemia may give results varying by more than 100% depending on orientation. Findings in normal-appearing regions containing a mixture of gray and white matter in patients (n = 5) and in normal volunteers (n = 6) show that Dav = (0.92+/-0.11) x 10(-3) mm2/s, with a small intersubject variation, whereas Dxx, Dyy, and Dzz vary strongly. Hemispheric ratios (ipsilateral/contralateral [I/C]) in these subjects were (I/C)Dav = 1.00+/-0.05, (I/C)Dxx = 1.02+/-0.15, (I/C)Dyy = 1.07+/-0.24, and (I/C)Dzz = 0.96+/-0.28. The individual subjects in this group all had an (I/C)Dav within 10% of unity, while the other three ratios showed intersubject variations as large as 100%. CONCLUSIONS: (I/C)Dav ratios are a reliable means to quantitate changes in absolute diffusion constants for the study of stroke evolution independent of tissue orientation, gradient orientation, and diffusion time. The use of these ratios will enable reproducible intersubject and interclinic quantitation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A M Uluğ, N Beauchamp, R N Bryan, P C van Zijl. 1997. Absolute quantitation of diffusion constants in human stroke.. https://doi.org/10.1161/01.str.28.3.483

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗