PubMed HealthSearch

PubMed · 908786

Vibrotactile frequency for encoding a speech parameter.

Abstract

Frequency of vibration has not been widely used as a parameter for encoding speech-derived information on the skin. Where it has been used, the frequencies employed have not necessarily been compatible with the capabilities of the tactile channel, and no determination was made of the information transmitted by the frequency variable, as differentiated from other parameters used simultaneously, such as duration, amplitude, and location. However, several investigators have shown that difference limens for vibration frequency may be small enough to make stimulus frequency useful in encoding a speech-derived parameter such as the fundamental frequency of voiced speech. In the studies reported here, measurements have been made of the frequency discrimination ability of the volar forearm, using both sinusoidal and pulse waveforms. Stimulus configurations included the constant-frequency vibrations used by other laboratories as well as frequency-modulated (warbled) stimulus patterns. The frequency of a warbled stimulus was designed to have temporal variations analogous to those found in speech. The results suggest that it may be profitable to display the fundamental frequency of voiced speech on the skin as vibratory frequency, thought it might be desirable to recode fundamental frequency into a frequency range more closely matched to the skin's capability.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Rothenberg, R T Verrillo, S A Zahorian, M L Brachman, S J Bolanowski. 1977. Vibrotactile frequency for encoding a speech parameter.. https://doi.org/10.1121/1.381610

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Acoustic probe-based ELISA.

The effects of acoustic microstreaming during incubation steps of a prototypical three-step ELISA were studied. Acoustic microstreaming, an orderly mixing of microwell contents induced by linear oscillation of immersible acoustic probes, was shown to be particularly effective when coupled with locating the solid phase on the surface of the probes. Optical densities achieved for acoustic probe-based assays were equivalent to those for uninsonated microwell-based assays with only 20% of the microwell solid phase surface area. Low-level antibody detection was significantly improved and antibody incubation times significantly shortened without loss of signal. Acoustic probe-based assays can enhance assay and laboratory efficiency through testing for multiple analytes in a single sample or increasing available binding surface area (by using probe and well surfaces simultaneously), and by eliminating quenching. Acoustic probe ELISA methodology has significant implications for cost-effective automation.

Acoustics