PubMed HealthSearch

PubMed · 909945

Pressure relief training device.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W C Temes, P Harder. 1977. Pressure relief training device.. https://doi.org/10.1093/ptj%2F57.10.1152

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Observation study of electronic portal images for off-line verification.

PURPOSE: The goals of this study were to evaluate the use of electronic portal imaging device (EPID) paper images as off-line verification tools and to assess the feasibility of replacing portal films by EPID printed images. MATERIALS AND METHODS: Electronic portal images were acquired using a video-based imaging system. After contrast enhancement, these images were printed and compared to portal films when prescribed, and judged about their usefulness for off-line verification. A total of 2025 images were acquired from 322 fields on 137 patients. The images were shown to eight radiation oncologists and two senior residents in radiation oncology, each one of them judging fields relevant to his (her) daily practice. The questions asked were related to the choice of important anatomical structures and the visibility of such structures, the usefulness of the printed images, the comparison with portal films and the possible replacement of such films by paper images. RESULTS: Answers to the different questions were treated as quantitative scores. For the visibility question, means and standard deviations were calculated for each individual structure, then a global score was obtained for a given treatment site. Means and standard deviations were also computed for the comparison question. Proportions and confidence intervals were used for the other questions. The results show that EPID paper images are useful for some treatment sites such as breast, thorax, prostate, abdomen, pelvis (other than rectum) and axilla. The image quality remains insufficient for some other sites such as head and neck and spine. CONCLUSION: Although global anatomical landmarks scores are good, the usefulness score is not always as high because some essential anatomical structures scores must be taken into account. There is also a strong habit factor related to acceptance of EPID printed images as verification tools. As long as they see more and more images, radiation oncologists can more easily visualize anatomical structures and are less stringent when evaluating the efficiency of EPID paper images as off-line verification tools.

Electronics, Medical

The accuracy of the Vivacare true pressure-sensitive periodontal probe system in terms of probing force.

BACKGROUND: The Hunter TPS Vivacare periodontal probe was invented to perform consistent, accurate and reliable periodontal examinations "with controlled pressures". AIMS: The aims of the present investigation are 3: (1) what is the accuracy of the probing force when various probe heads are used in a correct operation position; (2) what is the effect of over- and under-reading of the operation position on the probing force; (3) what is the accuracy of the probing force when different probe handles are used. The Hunter TPS probe consists of a tip connected to a special spring mechanism, which controls the pressure extended to the probe tip. According to the manufacturer, the force indicator lines coincide at approximately 20 g force. METHOD: The test apparatus consisted of an electronic balance, and an electronic caliper. 12 TPS probes tips and 3 handles were selected to test whether there were differences in force between probes. Each probe tip was adapted to the same handle and tested 10 times. In a 2nd test, the TPS handles and over-, accurate-, and under-readings were analyzed as to how they affect the probing force. The 12 TPS probe tips were connected to each of the 3 handles and tested 10x for each of 3 handles and levels. RESULTS: The range in force between TPS probe tips was 8.4 g (p<0.001). For the handles as well as for each of the readings of the operating positions, the differences were small and non-significant. However, between over- and under-readings, there were statistical significant differences. CONCLUSION: The conclusion is that the variation in force between probe tips is high and always above the manufacturer's "approximately" 20 g. As long as the same handle and the same probe tip are used together, and the examiner is reading the markings correct, the TPS probe is adequate.

Electronics, Medical

Transit dosimetry with an electronic portal imaging device (EPID) for 115 prostate cancer patients.

PURPOSE: Comparison of predicted portal dose images (PDIs) with PDIs measured with an electronic portal imaging device (EPID) may be used to detect errors in the dose delivery to patients. However, these comparisons cannot reveal errors in the MU calculation of a beam, since the calculated number of MU is used both for treatment (and thus affects the PDI measurement) and for PDI prediction. In this paper a method is presented that enables "in vivo" verification of the MU calculation of the treatment beams. The method is based on comparison of the intended on-axis patient dose at 5 cm depth for each treatment beam, D5, with D5 as derived from the portal dose Dp measured with an EPID. The developed method has been evaluated clinically for a group of 115 prostate cancer patients. METHODS AND MATERIALS: The patient dose D5 was derived from the portal dose measured with a fluoroscopic EPID using (i) the predicted beam transmission (i.e., the ratio of the portal dose with and without the patient in the beam) calculated with the planning CT data of the patient, and (ii) an empirical relation between portal doses Dp and patient doses D5. For each beam separately, the derived patient dose D5 was compared with the intended dose as determined from the relative dose distribution as calculated by the treatment planning system and the prescribed isocenter dose (2 Gy). For interpretation of observed deviating patient doses D5, the corresponding on-axis measured portal doses Dp were also compared with predicted portal doses. RESULTS: For three beams, a total of 7828 images were analyzed. The mean difference between the predicted patient dose and the patient dose derived from the average measured portal dose was: 0.4+/-3.4% (1 SD) for the anterior-posterior (AP) beam and -1.5+/-2.4% (1 SD) for the lateral beams. For 7 patients the difference between the predicted portal dose and the average measured portal dose for the AP beam and the corresponding difference in patient dose were both greater than 5%. All these patients had relatively large gas pockets (3-3.5 cm in AP direction) in the rectum during acquisition of the planning CT, which were not present during (most) treatments. CONCLUSIONS: An accurate method for verification of the MU calculation of an x-ray beam using EPID measurements has been developed. The method allows the discrimination of errors that are due to changes in patient anatomy related to appearance or disappearance of gas pockets in the rectum and errors due to a deviating cGy/MU-value.

Electronics, Medical