PubMed HealthSearch

PubMed · 9115016

Increased precision using countermatching in nested case-control studies.

Abstract

Nested case-control studies in occupational cohorts are often used to estimate exposure effects when development of detailed exposure estimates for all cohort members is too costly. Duration of exposure, which can act as a surrogate for cumulative exposure, is often readily available for all cohort members. Langholz and others have recently proposed a method of control selection called countermatching, which uses data on the surrogate to determine which controls are selected from the risk set for a given case. This method may increase precision relative to the usual random sampling of the risk set. We compare countermatching with random sampling in a nested case-control study of silicosis among miners. Data on cumulative exposure were in fact available for all cohort members, enabling estimation of the parameter of interest in the full cohort. We conducted nested case-control analyses using 100, 20, 10, and 3 controls per case using random sampling and additional analyses using 3 controls per case with two different methods of countermatching. All analyses were replicated 50 times to explore the statistical properties of the estimated exposure parameter. We found that one of the countermatching methods markedly increased efficiency compared with random sampling. Countermatching using 3 controls per case yielded an approximate 25% increase in relative efficiency compared with random sampling; it was approximately equivalent to random sampling using 10 controls.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Steenland, J A Deddens. 1997. Increased precision using countermatching in nested case-control studies.. https://doi.org/10.1097/00001648-199705000-00002

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Potential gain in efficiency and power to detect gene-environment interactions by matching in case-control studies.

BACKGROUND: There is growing interest in interactions between genetic and environmental risk factors of disease, but adequate power to detect such interactions in epidemiologic studies is of concern. The aim of this paper is to quantify the effect of matching on the efficiency of estimation and power to detect gene-environment interactions in case-control studies. METHODS: Starting from an empirical example in cancer epidemiology, we simulated frequency matched and unmatched case-control studies for a wide range of assumptions regarding the prevalence and the effects of an environmental and a genetic factor on disease risk as well as the quality and quantity of the interaction between these factors. Simulated studies were analyzed with multivariable logistic regression. RESULTS: Matching increased the efficiency and power in most scenarios. The gain was most pronounced in scenarios assuming a low prevalence of the environmental exposure. In such scenarios, equivalent power was only obtained with more than twice as many unmatched than matched controls. CONCLUSIONS: Frequency matching for known environmental risk factors with a low prevalence in the population may increase the efficiency of estimation and power of case-control studies to detect gene-environment interactions considerably. Investigators should weigh the gain in efficiency and power against known potential disadvantages of matching.

Case-Control Studies

Is lipoprotein(a)-cholesterol a better predictor of vascular disease events than total lipoprotein(a) mass? A nested case control study from the West of Scotland Coronary Prevention Study.

The clinical utility of a new assay for plasma lipoprotein(a)-cholesterol (Lp(a)-C) was assessed in parallel with our routine Lp(a) mass measurements in a nested-case control study of subjects within the placebo arm of the West of Scotland Coronary Prevention Study (WOSCOPS). A total of 238 control patients and 108 patients who had suffered a serious vascular event during the course of the WOSCOPS were examined. Lp(a) mass was assessed within 2 years of sampling by an ELISA method on baseline EDTA plasma samples which had been stored at -70 degrees C. Subsequently, the Lp(a) mass was re-measured by an immunoturbidimetric assay approximately 8 years after sampling. On the same stored aliquot the Lp(a)-C was measured. These analyses allowed us to assess whether the Lp(a)-C assay could provide any additional information over and above that which would be obtained from our Lp(a) mass assays. In addition the apo(a) isoform sizes of these subjects were measured using a high resolution immunoblotting system. The Lp(a)-C and Lp(a) mass measurements provided exactly the same information in the study, as they were equally non-discriminatory between cases and controls. The only difference between the two patient groups was the percentage of 'null' apo(a) alleles (control: 25.6% versus cases: 19.4%). We conclude that these results reinforce the concordance of the two assay systems and confirm that the Lp(a)-C assay provides no added information over and above that gained from traditional Lp(a) mass assays, which may be faster and less expensive.

Case-Control Studies

Cephalometric evaluation of the Twin-block appliance in the treatment of Class II Division 1 malocclusion with matched normative growth data.

Cephalometric radiographs were taken before and after treatment with the Twin-block appliance on 30 consecutive patients with Class II Division 1 malocclusions. A control group was generated from published normative data such that each treated case was matched individually for age, sex, and treatment time. The cephalometric change during treatment was compared to the natural growth change in the matched control group using a Mann-Whitney U-test for statistical significance. The treatment effect was also calculated by subtracting the natural growth change from the treatment change. This was then compared to twice the method error to see if the treatment change was clinically significant. There was both a statistically and clinically significant reduction in overjet, angle ANB, increase in angle SNB, and mandibular length together with a reduction in upper incisor angle. None of the other cephalometric parameters measured showed a significant change.

Case-Control Studies