[Simple, practical closed-circuit anesthesia].

Abstract

The practice of closed-circuit anesthesia provides many advantages, including conservation of body heat and airway humidity, hemodynamic stability, minimization of operating room as well as environmental pollution, and a saving of up to 90% in consumption of anesthetics. However, the misunderstanding of the theory of the uptake of inhalation anesthetics has hampered the clinical practice of closed-circuit anesthesia. With proper recognition of the existence of the functional residual capacity and the alveolar membrane, a new concept of uptake of inhalation anesthetics has been developed: (1) uptake is dependent on the inspired concentration; (2) the functional residual capacity is a part of the anesthetic circuitry; and (3) uptake should be represented by 1-FA/FI. This physiologic and common-sense approach to understanding the processes of uptake of inhalation anesthetics greatly facilitates the practice of closed-circuit anesthesia. This new approach not only provides for a simple calculation of the minute to minute requirement for anesthetic vapors, depending on the desired inspired anesthetic concentration, but also enables one to practice closed-circuit anesthesia easily and safely with the currently existing anesthetic equipment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Y Lin. 1997. [Simple, practical closed-circuit anesthesia].. https://pubmed.ncbi.nlm.nih.gov/9128021/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Pros and cons of adding an accessory breathing system to the main circle circuit. II. Arguments against their use].

When compared to the circle system alternative breathing systems (ABS) are of no benefit. When the only indication of an ABS is emergency oxygen administration it should be connected to the O2 pipeline upstream from the flowmeter bank and the vaporiser. The use of an ABS for anaesthesia maintenance is no longer justified because of the difficulties in monitoring pressure, flow and concentrations of the gas mixture, the cost of gas and vapour administered at a high flow and the resulting pollution. The use of an ABS for very short anaesthetics is only acceptable if the administered gas mixture is monitored.

Anesthesia, Closed-Circuit

Methane influences infrared technique anesthetic agent monitors.

OBJECTIVE: During closed-circuit anesthesia, anesthetic vapor analysis by infrared absorption at 3.3 microm can be influenced by the concentration of accumulated methane, resulting in inaccurate readings of anesthetic concentrations. The current study examined the influence of different known methane concentrations on the analysis of halothane or isoflurane concentrations by the infrared absorption technique. METHODS: Three different gas mixtures containing 100, 500 and 1000 ppm methane were given through an experimental sampling bar. Four infrared technique anesthetic agent monitors were examined: (1) the Ultima (Datex), (2) the Andros analyzer (Cato anesthesia machine, Driger), (3) the anesthetic gas monitor 1304 (Brüel & Kjaer) and (4) the mainstream analyzer Irina (Drager). All devices, except the Brüel & Kjaer anesthetic gas monitor, function at 3.3 microm wavelength. The Brüel & Kjaer apparatus functions at 10.3-13 microm wavelength. The readings were recorded with and without addition of halothane (or isoflurane) at a halothane (or an isoflurane) dedicated sensitivity after application of methane. RESULTS: At the two highest methane concentrations (500 and 1000 ppm) all studied devices except the Brüel & Kjaer anesthetic gas monitor 1304 displayed inaccurate anesthetic concentrations. This was more pronounced at halothane than at isoflurane sensitivity. Introduction of halothane (0.8%) or isoflurane (0.8%) vapor into the experimental sampling bar resulted in values that were additive to the falsely recorded ones. CONCLUSIONS: In closed circuit or low-flow anesthesia, in which methane can accumulate, infrared measuring techniques for potent inhalation anesthetics that do not use the 3.3 microm wavelength appear to be preferable.

Anesthesia, Closed-Circuit